INSTALLATION
.
❒ Turn power off at the fuse or circuit breaker.
This model Instant Motion Sensor Light Control can be
used with many indoor or outdoor light fixtures where
the motion sensing feature is desired.
Keep the lamp at least 1"
(25mm) from the sensor
and cord.
NOTE: Do not stretch the coils too tight when installing
the remote sensor. The coils are needed to create a
drip loop to prevent water from running into the fixture
or the sensor.
❒ Open the light fixture if it
is necessary. Remove the
light bulb. Screw in the lamp
module and replace the
bulb.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Mounting Sensor
Wall Mount
❒ Mount the sensor 5 to 9 feet (1.5 to 2.7 meters) above
the ground. Place the sensor below or beside the
lighting fixture so that the light from the fixture
will not hit the sensor. Secure the sensor to the
wall with the screws provided. It will be necessary
to tilt the sensor head to the side when mounting.
NOTE: Mounting the sensor directly above the lamps
may increase false triggering.
❒ Plug the adapter
cord(s) into the
sensor module.The
adapter cord's plug
is polarized for proper
installation.
❒ The sensor/control is capable of controlling two lamp
adapters. This illustration shows a typical installation
with two lamp adapters controlling PAR-38 lamps.
Note the sensor is below the lamps and there is
sufficient cord from the adapters to form a drip
loop to prevent water from
running down the cords
and into the
sensor. Also,
t h e l a m p s
m u s t s t a y
at least 1"
(25mm) from
the sensor.
2
Ceiling Mount
595-5734-04