TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on or when switching from Manual to Auto
mode wait 1
❒ Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST
position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
5 to 9'
(1.5-2.7 m)
Maximum Range
595-5734-04
/
minute warm up period
1
2
/
minutes.
1
2
SENS
MIN
60 ft.
(18m)
Maximum
Coverage Angle
The detector is less sensitive to motion directly towards
it and more sensitive to cross motion.
Motion
Least Sensitive
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.
❒ Adjust the SENSITIVITY as
MAX
needed. Too much sensitivity
may increase false triggering.
❒ Set the amount of TIME you
want the lights to stay on after
motion is detected (1, 5, or 10
minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60' (18m) [varies with
Sensing Angle . . . . . . . Up to 110°
Electrical Load. . . . . . . Up to 150Watts Maximum (per
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1 , 5, 10 minutes
Sensitivity . . . . . . . . . . Adjustable
110°
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
3
Motion
Sensor
Most Sensitive
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
adapter) Incandescent.