Intended Use; Technical Data - Festool VAC SYS SE Manual De Instrucciones

Unidad de sujeción por vacío
Ocultar thumbs Ver también para VAC SYS SE:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

birth defects or other reproductive harm. Some ex-
amples of these chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement and
other masonry products, and
• arsenic and chromium from chemically treated
lumber.
The risk from these exposures
varies, depending on how often
you do this type of work. To re-
duce your exposure to these
chemicals: work in a well ven-
The vacuum clamping system VAC SYS SE is de-
signed for clamping objects with flat, smooth, air-
tight surfaces in combination with vacuum pump
VAC PMP.
For general purposes use the standard issue VAC
SYS SE 1. To secure very large objects (i. e. doors)
add a secondary clamping unit of the type VAC SYS
Vacuum clamping system
Weight VAC SYS SE 1
Weight VAC SYS SE 2
Holding force of the vacuum clamping unit
Suction plate
D 215
275x100
200x60
277x32
1.
Specifications for smooth surfaces such as PMMA (plexiglas®), PF hard fibre (Resitex) and worktops, not for MDF or similar materials.
2.
The holding force may decrease by up to 20% over the course of the years. Values relate to a vacuum of 85% (150 mbar end pressure)
and include a safety factor of 2.
Maximum workpiece dimensions
Suction plate
D 215
275x100
200x60
8

Intended use

Technical data

Holding force 90° tilted
(workpiece position vertical)
121 lb (55 kg)
77 lb (35 kg)
48 lb (22 kg)
46 lb (21 kg)
Maximum dimensions
3-1/4 ft x 3-1/4 ft (1 x 1 m)
3-15/16 ft x 1-5/16 ft (1,2 x 0,4 m)
2-5/8 ft x 5/8 ft (0,8 x 0,2 m)
tilated area, and work with approved safety equip-
ment, such as dust masks that are specially de-
signed to filter out microscopic particles. Wash
hands after handling.
WARNING
TO REDUCE THE RISK OF INJURY, USER MUST
READ INSTRUCTION MANUAL.
SE 2. Use both types simultaneously by connecting
them via the foot valve.
The Vacuum pump VAC PMP and the secondary
clamping unit VAC SYS SE 2 may or may not be in-
cluded, according to which set you have chosen.
The user is liable for improper or non-in-
tended use.
1, 2
Holding force 0° tilted
position horizontal)
1
VAC SYS SE
18 1/3 lb (8.3 kg)
17 2/3 lb (8.1 kg)
1, 2
(workpiece
200 lb (90 kg)
115 lb (53 kg)
66 lb (30 kg)
60 lb (27 kg)
1
Maximum weight
200 lb (90 kg)
115 lb (90 kg)
66 lb (30 kg)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vac sys se 1

Tabla de contenido