Dometic Origo 5100 Instrucciones De Uso página 10

Ocultar thumbs Ver también para Origo 5100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Using the heater
➤ Fill the denatured alcohol through the wire mesh into the opening of the
canister (8).
The maximum capacity per canister must not exceed 1.2 l.
➤ Check the fuel level by tilting the canister (8) vertically (fig. 3, page 4).
Keep it in this position for 20 s, to make sure it's not overfilled. In addition, in the
case of accidental overfilling you can get rid of the surplus fuel.
✓ The maximum fuel level is reached when the fuel is visible in the recess inside the
canister opening (fig. 3, page 4).
I
NOTE
The heater will operate even if the canister isn't filled with the maximum
capacity.
➤ Wipe possible spilt alcohol off the outside of the canister (8).
➤ Fasten the burner (4) to the canister (8).
Ensure that the four springs (7) hold the canister.
➤ Place the unit of canister (8), burner (4) and grid (3) into the heater.
Ensure that the lock springs (10) hold this unit.
7.2
Lighting the heater (fig. 1, page 3)
!
CAUTION!
Quickly remove your hand as soon as the burner ignites.
➤ Take off the top cover (1).
➤ To open burner (4), pull out the regulator (5) and turn it to the left (ON).
➤ Place a lighter in the ignition hole of the burner (4) and light it.
I
NOTE
If the heater hasn't cooled down from previous use, the burner may
ignite but immediately extinguish. In this case blow air into the burner
opening to dissipate vapour.
Afterwards light the heater as described above.
➤ Adjust the flame so it does not extend beyond the edge of the pot.
– To increase the heat, turn regulator (5) towards left (ON).
– To reduce the heat, turn regulator (5) towards right (OFF).
10
Origo
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Origo5100

Tabla de contenido