Designation
S5 - S6
S8
S9
S10
S11 - S12 - S13
S14 - S15 - S16
S17
S18 - S19
S20 - S21
S22 - S23
S26 - S27
S28
S29
S30
S34
S35
S36
S37
S38-S39
S40-S41
(**)
(*)
(**)
Type 1007 1015 1022 1030 2040 2055 2075 3110 3150 4185 4220 4300 4370 5450 5550 6750 7900 71100 71320 81600 82000
S3-1
ON
OFF
ON
S3-2
OFF
ON
ON
S3-3
OFF OFF OFF OFF
S3-4
OFF OFF OFF OFF OFF OFF OFF OFF OFF
S3-5
ON
ON
ON
S3-6
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
S3-7
ON
ON
ON
S3-8
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
En las condiciones de suministro estándar, los aparatos ya vienen preparados correctamente. ¡Cuando la tarjeta de regulación se
haya suministrado como recambio, colocar el interruptor S3 para el tamaño deseado!
Cap.5
66
Tabla 5.3.1.2: Puentes en la tarjeta de regulación RV33
Terminating resistor for the serial interface RS485
ON= Termination resistor IN
OFF= No termination resistor
Adaptation to the input signal of analog input 1 (terminals 1 and 2)
ON=0...20 mA / 4...20 mA
OFF=0...10 V / -10...+10 V
Adaptation to the input signal of analog input 2 (terminals 3 and 4)
ON=0...20 mA / 4...20 mA
OFF=0...10 V / -10...+10 V
Adaptation to the input signal of analog input 3 (terminals 5 and 6)
ON=0...20 mA / 4...20 mA
OFF=0...10 V / -10...+10 V
Encoder setting ( jumpers on kit EAM_1618 supplied with the drive)
ON=Sinusoidal SE
OFF=Digital DE
Monitoring of the C-channel of the digital encoder
ON=C-Channel monitored
OFF=C-Channel not monitored (required for single-ended channels)
Encoder setting
Pos. B= reserved
Pos. A= reserved
Analog input 3 enabling (alternative with SESC encoder)
Pos. A= reserved
Pos. B=analog input 3 enabled
Pos. OFF= resolver
Reserved
Encoder Internal power supply selection
ON / ON = +5 V
OFF / OFF = +8 V
Internal use
Second encoder qualifier input
A=from EXP-... board
B=from digital input "3" on RV33-4
Jumper to disconnect 0V (+24V power supply) from ground
ON = 0V connected to ground
OFF = 0V disconnected from ground
Jumper to disconnect 0V (regulation board) from ground
ON = 0V connected to ground
OFF = 0V disconnected from ground
Internal use
Internal use
Internal use
Power supply for the serial interface RS485
ON = Internal power supply (from pins XS.5 / XS.9)
OFF = External power supply (to pins XS.5 / XS.9)
on multidrop connection the jumper must be ON only for the last drop of a serial line
see chapter 5.4
Tabla 5.3.1.3: Interruptor S3 de adaptación de la tarjeta RV33
OFF OFF
ON
OFF
ON
OFF OFF OFF
ON
ON
ON
OFF OFF OFF
OFF
ON
OFF OFF OFF OFF
ON
ON
ON
ON
ON
Function
OFF OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF OFF
ON
ON
ON
ON
ON
OFF OFF OFF OFF
ON
OFF OFF OFF
ON
ON
OFF OFF OFF OFF OFF OFF OFF
ON
ON
ON
ON
ON
ON
AVyGR - ES
Factory setting
ON (*)
ON/ON
(hard-wire)
(hard-wire)
not mounted
not mounted
ON
OFF
ON
OFF
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
B
B
ON
A
A
ON
ON
ON
OFF
Ay4060
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
avy4080