3.3
Charging procedure
•
Only charge GESIPA
Take the quick charger out of its packaging and connect to the power supply. Pay atten-
•
tion to the voltage specified on the rating plate!
•
Using minimum force, insert the GESIPA
into the charger.
•
The charging operation starts automatically.
Function indicators
Steady green
Flashing green
Steady red
Flashing red
Charging times
Battery type
1.3 Ah
2.6 Ah
* Charging times may vary depending on the residual capacity and the battery temperature.
3.4
Battery care
•
To achieve an optimum charge, allow the battery to cool down before inserting it in the
charger.
•
The GESIPA
battery can be recharged approx. 1000 times and reaches its full capacity
®
after several charges.
•
Do not insert the battery into the charger after each use.
•
Only charge the battery when it is discharged and blind rivet nuts can no longer be set.
Only recharge the battery after a prolonged idle period.
•
Significantly shorter battery operating times, despite proper recharging, indicate that the
battery needs to be replaced.
•
Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10 °C to max. 50 °C.
batteries at a temperature between 0 °C and 40 °C!
®
Battery charged / trickle charging
Charging
Impermissible charging temperature
Battery defective
Part No.
143 4921
145 7269
battery in the correct position (+pole to +pole)
®
Charging time*
approx. 50 min
approx. 100 min
GB
25