3.3

Charging procedure

Only charge GESIPA
Take the quick charger out of its packaging and connect to the power supply. Pay atten-
tion to the voltage specified on the rating plate!
Using minimum force, insert the GESIPA
into the charger.
The charging operation starts automatically.

Function indicators

Steady green
Flashing green
Steady red
Flashing red

Charging times

Battery type
1.3 Ah
2.6 Ah
* Charging times may vary depending on the residual capacity and the battery temperature.
3.4

Battery care

To achieve an optimum charge, allow the battery to cool down before inserting it in the
charger.
The GESIPA
battery can be recharged approx. 1000 times and reaches its full capacity
®
after several charges.
Do not insert the battery into the charger after each use.
Only charge the battery when it is discharged and blind rivet nuts can no longer be set.
Only recharge the battery after a prolonged idle period.
Significantly shorter battery operating times, despite proper recharging, indicate that the
battery needs to be replaced.
Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10 °C to max. 50 °C.
batteries at a temperature between 0 °C and 40 °C!
®
Battery charged / trickle charging
Charging
Impermissible charging temperature
Battery defective
Part No.
143 4921
145 7269
battery in the correct position (+pole to +pole)
®
Charging time*
approx. 50 min
approx. 100 min