FALLA:
POSIBLE CAUSA:
__________________________________________________________________________________
VARIA
SUCIEDAD DE CUCARACHAS
FALSO CONTACTO EN CONECTOR
DE LA CELDA
CELDA CON HUMEDAD O SUCIEDAD
`
BATERIA DESCARGADA
__________________________________________________________________________________
NO PESA
CELDA DAÑADA
CONECTOR DE LA CELDA ALREVEZ
TOPE DE SOBRECARGA, MUY ALTO
FACTOR ALTERADO
__________________________________________________________________________________
PESA MAL
SUCIEDAD DE CUCARACHAS
OBSTRUCCION EN EL DESPLAZA-
MIENTO DE LA CELDA
DESAJUSTADA
HELP
CELDA DAÑADA
__________________________________________________________________________________
FALTAN
DISPLAY DAÑADO
SEGMENTOS
( EN UNO SOLO)
POSIBLES FALLAS
34
SOLUCIONES:
LIMPIEZA GRAL. DE LA SECCION
ANALOGA.
MOVER EL CONECTOR DE LA
CELDA DE CARGA, SI SE DETECTA
QUE ES EL CONECTOR, CAMBIAR
EL CONECTOR O SOLDAR DIRECTO
PROBAR CON OTRA CELDA DE
CARGA, SI LE QUITA LA VARIACION
CAMBIAR LA CELDA
CHECAR SOLO CON ELIMINADOR
YCHECAR SI SE ELIMINA LAFALLA
PROBAR CON OTRA CELDA,SI NO
PESA, CAMBIARLA.
CHECAR CONECTOR DE CELDA
CHECAR QUE EL TOPE DEJE EL
LIBRE MOVIMIENTO DE LA CELDA
TRATE DE RECALIBRAR LA
BASCULA DE ESTA MANERA SE
REESTABLECE EL FACTOR Y LA
BASCULA
VUELVE
CORRECTAMENTE.
LIMPIEZA GRAL. DE LA SECCION
ANALOGA
CHECAR QUE LA CELDA NO ROCE
CON EL GABINETE, QUE NO HAYA
OBJETOS DEBAJO /PORTAPLATO
CHECAR QUE NO HAYA SIDO ALTE-
RADA LA CALIBRACION, POR LO
QUE SE PROCEDERA A CALIBRARA
Y EVALUAR.
CHECAR LAS CONDICIONES DE LA
CELDA O EN SU DEFECTO, PROBAR
CON OTRA.
RESOLDAR PATITAS DEL DISPLAY,
CHECAR CON OTRO DISPLAY
CHECAR FALSOS EN CONECTORES
A
PESAR