Start generator
as described
in the section
"Starting
the Engine", then place carton
over generator.
Keep at
least 5 ft. (152 cm) clearance
on all sides of generator
including overhead
with shelter
in place.
WARNmNG
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Remove shelter when temperatures
are above 40°F [4°C].
7.
Remove
shelter when
temperatures
are above 40°F
[4oc].
8.
Turn engine OFF and let cool two (2) minutes before
refueling.Wipe
up any spilled fuel.
Creating
a Permanent
Shelter
I.
Build a structure
that will enclose
three
sides and the
top of the generator,
making sure muffler side of
generator
is exposed.
NOTE:
Structure
should
hold enough
heat created
by the
generator
to prevent
icing problem.
2.
DO NOT enclose
generator
any more
than shown in
Figure 4.
NOTE:
If a wheel kit is installed on the generator,
enlarge
shelter
accordingly.
3.
Follow steps 3 through
8 as described
previously
in
"Creating
a Temporary
Shelter".
RECEPTACLES
A double pole rocker
switch
circuit breaker
is provided
to
protect
all the receptacles
and generator
against electrical
overload.
NEVER attempt to power a device requiring more amperage
than generator
or receptacle can supply.
DO NOT overload the generatom: See "Don't Overload
Generator
_',
[ 20/240
Volt AC, 20 Amp
Locking
Receptacle
Use a NEP1A LI4-20
plug with this receptacle.
Connect
a
4-wire
cord set rated for 250Voks
AC at 20 Amps (or
greater)
(Figure 5).You can use the same 4-wire
cord if you
4an to run a 120Vok load.
,"
iiii,
4-Wire Cord Set
(Neutral)
Y (Hot)
|
X (Hot)
NEMA
L14-20
_
Ground (Green)
This receptacle
powers
120i240VokAC,
60 Hz, single
phase loads requiring
up to 2,000 watts
of power
at
16.6 Amps for 120Volts; 4,000 watts
of power
(4.0 kVV) at
16.6 Amps for 240Volts.The
outlet
is protected
by a
double pole rocker
switch circuit breaker.
IMPORTANT:
This generator's
locking receptacle
and the
provided
adapter
cord set are not protected
by a Ground
Fauk Circuit
Interrupter
(GFC[). If used on an OSHA
governed
job site, appropriate
GFCI protection
must be
utilized.
[ 20Volt
AC,
[ 5 Amp,
GFC[
Duplex
Receptacles
Each duplex receptacle (Figure 6) is protected
against
overload by a push-to-reset
circuit breaker.
NOTE:
If the double pole circuit breaker [s tripped, the
duplex receptacles are disconnected.
Use each receptacle to operate
120VoltAC,
single-phase,
60 Hz electrical
loads requirhg
up to 1,800 watts (1.8 kV_)
at 15 Amps of current.
Use cord sets that are rated for
125 Volt AC loads at I5 Amps (or greater).
Inspect
cord
sets before
each use.