Using The Appliance; Maintenance; Emptying The Dust Container; Replace Uv-C Lamp Whenever The Need Arises - Profi Care PC-MS 3079 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17

Using the Appliance

NOTE:
• Always test the appliance on a small, insignificant spot
first.
• Make sure to always clean mattresses on both sides.
1. Insert the mains plug into a correctly installed power
socket.
2. Place the appliance on the surface to be cleaned.
3. Use the on / off switch
to put the appliance into
operation.
4. Press and hold the vibration button on the bottom of the
handle. The surface to be cleaned is shaken due to the
vibration and the dust will be sucked up. In addition, the
UV-C lamp turns on.
5. Move the appliance slowly and evenly over the surface
to be cleaned.
6. Maintain an offset when positioning the appliance as the
track width of the suction is limited by design.
7. Use the on / off switch
to put the appliance out of
operation.
WARNING:
• Before cleaning remove the mains lead from the socket.
• Under no circumstances should you immerse the appliance in
water for cleaning purposes. Otherwise this might result in an
electric shock or fire.
CAUTION:
• Do not use a wire brush or any abrasive items.
• Do not use any acidic or abrasive detergents.
Clean the housing with a soft, dry cloth without additives.

Dust Container and HEPA Filter

1. Remove the dust container by pulling it up via the
handle.
2. Then remove the filter from the dust container.
3. Empty the dust container. Rinse, if necessary.
4. Brush out the filter. If heavily soiled, you may clean the
filter under running water.
PC-MS3079_IM
NOTE:
Replace the filter and the UV-C lamp whenever the need
arises.

Emptying the Dust Container

Empty the dust container after each use.
1. Disconnect the mains plug from the socket.
2. Remove the dust container by pulling it up via the
handle.
3. Then remove the filter from the dust container.
4. Empty the dust container.
5. Place the filter back into the dust container.
6. Put the dust container back into the appliance.

Replace UV-C Lamp whenever the Need Arises

In case the UV-C lamp is defective, you can replace it.
1. Disconnect the mains plug from the socket.
2. Loosen the screw on the cover that is located at the
bottom of the appliance using a Phillips screwdriver.
3. Remove the cover.
4. The UV-C lamp is attached to two pin bases. Carefully
pull them up and detach the UV-C lamp from the pin
bases. Replace it with a UV-C lamp of the same type.
5. Put the UV-C lamp back in a reverse order and reattach
the cover.

Cleaning

5. Allow all parts to dry completely before putting them back
into the appliance!
6. Place the filter back into the dust container.
7. Put the dust container back into the appliance.
• Clean the appliance as described and allow it to dry.
• We recommend that you keep the appliance in the origi-
nal packaging if it will not be used for long periods.
• Always store the appliance out of the reach of children in
a dry, well ventilated place.

Maintenance

Storage

20.04.20
27

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido