Training Of Personnel; Fault Localisation, Troubleshooting - ABNOX AXDV-P1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47

Training of Personnel

Only trained and instructed personnel who have read
and understood all points of the Operating Manual
may work on the product. Likewise the individual
operating states must be mastered, and the related
safe aspects must be known and they must be able
to implement them. Personnel undergoing training
may only work on the product under the supervision
of qualified personnel.

Fault Localisation, Troubleshooting

CAUTION
Remediation of any of the faults
described below may only be
carried out by a trained technician.
Fault
The impulse valve switches but
no lubricant is ejected
The impulse valve switches but
no lubricant is ejected
The dosing valve is leaking
The dosing valve is leaking
Air in the system
Leaky valve
Irregular dosing
Possible cause
The feed pump is not supplying
lubricant
Material pressure too low
The control air pressure/
counter-pressure of the spring is
too low
Defective seals
Air pockets in the grease
container
Air pockets in the hoses
Defective seals
No constant grease and air
pressure.
Corrective action
Consult the operating manual for
the feed pump
Increase pump pressure
Increase the control air pressure
Install a stronger spring
Replace seals
Loosen supply hose. Bleed system.
Then re-tighten supply hose.
Replace seals
Upstream installation of optional
material pressure regulator MDR
EN
23

Publicidad

Tabla de contenido
loading

Tabla de contenido