Error Correction; Led Indicators - Vogel's PPA-350 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
Manual Mode Control
The following functions will work only after entering Manual Mode.
Function
Set Show position (all the way up)
Set Maintenance position
Exit Manual Mode

Error Correction

Stop Error blinks
Override 7 Blinks

LED Indicators

RED LED
GREEN LED OFF
Slow Blink
Fast Blink
Fast Blink
Intermittent Blinking
Fast Blink
Pin Assignments: DB9 Male to DB9 Female
1 Black - UP
2 Red – DOWN
3 Green – STOP
4 Blue - SET
5 Yellow - OVERRIDE
6 White Common
7 Purple - LED
8 Orange – Safety Switch Override
9 Brown +5V
Button
Hold HIDDEN for one second, release,
then press and release UP
Hold HIDDEN for one second, release,
then press and release DOWN
Hold HIDDEN for one second, release,
then press and release STOP
Press and hold STOP for 10 seconds
Press and hold STOP for 10 seconds,
release, then press and hold HIDDEN for
five seconds, release, press UP. Lift will
raise, release the limit switch and stop.
Same as Lift codes
In Automatic Mode
In Manual Mode
Hidden button pressed for 5 seconds,
waiting for next button push – or-
Confirmation of Set Show/Maintenance
Reception of IR signal
20 times Powered up
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ppa-360

Tabla de contenido