5. About Remaining Battery Indicator
When pressing the remaining battery indicator switch,
the remaining battery indicator lamp lights and the
battery remaining power can be checked. When
releasing your fi nger from the remaining battery
indicator switch, the remaining battery indicator lamp
goes off . The Table 4 shows the state of remaining
battery indicator lamp and the battery remaining
power. (see Fig. 1)
State of lamp
Battery Remaining Power
The battery remaining power is
enough.
The battery remaining power
is a half.
The battery remaining power is
nearly empty.
Re-charge the battery soonest
possible.
As the remaining battery indicator shows somewhat
diff erently depending on ambient temperature and
battery characteristics, read it as a reference.
NOTE
○ Do not give a strong shock to the switch panel or
break it. It may lead to a trouble.
○ To save the battery power consumption, the
remaining battery indicator lamp lights while pressing
the remaining battery indicator switch.
6. Using the hook
The hook is used to hang up the power tool to your
waist belt while working.
CAUTION
● When using the hook, hang up the power tool
fi rmly not to drop accidentally.
If the power tool is dropped, it may lead to an
accident.
● When carrying the power tool with hooked to
your waist belt, do not fi t any bit to the tip of
power tool. If the sharp bit such as drill is fi tted
to the power tool when carrying it with hooked to
your waist belt, you will be injured.
● Install securely the hook. Unless the hook is
securely installed, it may cause an injury while
using.
(1) Installing the hook and tightening the screws.
Install securely the hook in the groove of power
tool and tighten the screws to fi x the hook fi rmly.
(Fig. 9)
Hook can be installing either side of the body.
Table 4
Body
Hook
7. Using the light
Pull the trigger switch to light up the light. The light
keeps on lighting while the trigger switch is being
pulled. The light goes out after releasing the trigger
switch. (Fig. 10).
Trigger
Switch
CAUTION
Do not look directly into the light. Such actions
could result in eye injury.

OPERATIONAL CAUTIONS

1. Resting the unit after continuous work
(1) The power tool is equipped with a temperature
protection circuit to protect the motor.
Continuous drilling or tightening wood screw work may
cause the temperature of the unit to rise, activating
the temperature protection circuit and automatically
stopping operation.
If this happens, allow the power tool to cool before
resuming use.
(2) After use for continuous tightening wood screw works,
rest the unit for 15 minutes or so when replacing the
battery. The temperature of the motor, switch, etc.,
will rise if the work is started again immediately after
battery replacement, eventually resulting in burnout.