Descargar Imprimir esta página

Technical Specification - Bresser 70-20000 Instrucciones De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58
4. Status of the gateway (after power on)
Green LED:
Continuous flashing for about 30 seconds: scanning for installed sensors or registering new sensors
Always lit up and flashing once every 30 seconds: normal operation (receiving sensor data)
Continuous flashing for a long time or not lit up for a long time: abnormal behavior
Red LED:
Light up for around 3 seconds: system start-up
Always off: App is not running or remote access is not yet activated. Otherwise abnormal.
Flashing every 5 seconds: LAN cable is not properly connected to the gateway and/or an IP address has not been as-
signed to the gateway (no connection to the internet). Check the cable connection and whether DHCP is set in router
configuration (please refer to the router user manual on how to check).
Always lit up: App is running and/or remote access is activated. Otherwise abnormal
5. Firmware upgrade
When starting to run the app, there will be a pop-up message asking for a firmware upgrade if either one or both of the
gateway firmware versions are found outdated. There are two firmware – device firmware (router-gateway) and RF firmware
(gateway-sensors) and the upgrade has to be done one after the other separately. After upgrade, the system may become idle
for several minutes and then reboot automatically (the red and green LEDs will flash). If the automatic reboot fails (either one
or both LEDs do not flash after several minutes), please manually power off and then power on the gateway, and wait several
minutes for reboot. To check whether the upgrade has been successful, press the 'i' icon on the top left corner to see the
firmware version numbers.
Soil moisture sensor
1. Soil sensor does not increase moisture level immediately after watering:
Cause: Soil moisture sensing cycle is 10 minutes
Solution: Wait for up to 10 minutes until the next cycle of soil moisture sensing has updated the moisture level displayed after
watering. If the sensor is inserted deeply into the soil, wait for some more time to allow for water to diffuse through the covering
soil.
2. Soil moisture reading shows lower level than expected
Cause #1: Soil texture may affect the measurement result
Solution: Avoid using soil sensor in soil with extreme texture (too much sand or clay), or adjust the meaning of the levels ac-
cording to the observed soil moisture conditions
Cause #2: Some air space is hidden inside the soil
Solution: Remove and insert again the sensor in another position of soil.
Cause #3: Sensor probe is not inserted deep enough into the soil.
Solution: Push the probe down until the soil moisture sensor (or soil temperature sensor) reaches the root (or seedbed) level
or about two thirds of the depth of the pot. Never insert the sensor deeper than the maximum indicated in fig. 7 (A).
Cause #4: The metal pins of the sensor probe are oxidized or coated with dirt
Solution: Slightly polish the surface of the metal pins (Fig. 7, B).
Router compatibility
Please visit the link below for details of router compatibility
http://iConnect.netinfostation.com
Any conventional router for home networking applications that is allowing network devices to connect to it should be able to
work with the gateway.
Check the user manual and FAQ of your router model, or ask the router manufacturer to find out if inter-device communication
is enabled by default.

Technical Specification

System requirements:
iOS version 4.3 or above (iPhone 3GS or above; iPod touch 4th generation or above; iPad)
Android version 2.3.3 or above (Android phone with a display resolution of 320 x 480 pixels or above)
Wireless WiFi router that supports inter-communication between the devices that are connected to different ports of the
router.
Internet connection
Mobile internet connection for remote access of the BRESSER Connect if outside of the WiFi connection area
(Please visit http://iConnect.netinfostation.com or "Router Compatibility" section for more details of the Smartphone com-
patibility)
Note: Due to variations in the Internet protocol implementation, some Android devices that meet the above requirements,
can still cause problems while running the app.
(Please visit http://iConnect.netinfostation.com for more details of the Smartphone compatibility)
DE
GB
FR
NL
IT
ES
23

Publicidad

loading