6.4 Preventive Maintenance Programme
To guarantee lasting maximum dryer effi ciency and reliability:
Maintenance
Activity description
Activity
Control
Service
Check the POWER ON indicator is lit.
Check control panel indicators
Check the correct level of the fl ow meter.
Check condensate drain.
Clean condenser fi ns.
Check electrical absorption
Depressurize the unit.
Complete drain maintenance
Depressurize the unit.
Substitute pre- and post-fi lter elements.
Substitute fi lter element, oil separator fi l-
ter and dust preventer fi lter.**
It is recommended to replace the pressure
dew point sensor.
Main solenoids- change
Check the silencer yearly and when
change the desiccant agent
No return Valve- change
Solenoids Drain- change
Desiccant agent
Y
**
Refer to the manufacture date of the machine, written in the
data label.
Maintenance work must be performed by authorized personnel.
Maintenance Interval
(standard operating
All spare parts and their respective codes can be found listed on sec-
conditions)
tion 9.4.
Contact supplier
For any maintenance please note the following warnings:
During the replacement of any fi lter element, ensure the perfect closing
of the fi lter, checking the correct alignment of symbols on the head and
the housing.
!
DANGER: A misalignment of these, could result in the expul-
sion of the housing during pressurization of the system, with the conse-
quence of projection hazard of bodies against persons of things.
!
DANGER MACHINE UNDER TENSION
Not perform maintenance while the machine is under tension or under
pressure.
Do not remove any covers of the dryer.
!
DANGER HAZARDOUS VOLTAGE!
!
DANGER MACHINE UNDER PRESSURE
!
Not perform maintenance while the machine is under pressure,
perform the following action:
1) Depressurize the compressed air system;
2) Make sure that the pressure on both gauges = 0 bar
(AIR IN "n°22");
!
Warning: the dryer is still under pressure in the
"AIR OUTLET SIDE" of the cooler
Depressurize the dryer using a valve- "air out cooler"
3)
(if installed by the user) or use the drain-valve of the
dust-fi lter (29).
Make sure that the pressure on gauge = 0 bar
4)
(AIR OUT "n°35").
ATT060-090
Z
!
Th e desiccant vessels are designed (EN 13445-3) for fatigue opera-
tion with continuous cycles of loading and unloading for a maximum
period of:
20 years for models 60-90.
6.5 Dismantling
Th e refrigerant and the lubricant oil contained in the circuit must be re-
covered in conformity with the current local environmental regulations.
Th e refrigerant fl uid is recovered before fi nal scrapping of the equip-
ment ((EU) No. 517/2014 art.8).
• %
Recycling Disposal
Structural work
steel/epoxy-polyester resins
exchanger
alluminium
pipes
alluminium/copper/steel/iron
drain
polyamide
exchanger isolation
EPS (sintered polystyrene)
pipe isolation
synthetic rubber
compressor
steel/copper/alluminium/oil
condenser
steel/copper/alluminium
Refrigerant
R407c
Valves
brass
electrical cables
copper/PVC
vessel
steel/epoxy resins
fi lter vessel
steel/epoxy resins
fi lter elements
contact supplier
valve blocks
alluminium
dessicant agent
contact supplier
8 / 14
Z