Airflow direction adjustment
Up/down direction can be adjusted with the AIRFLOW
button the mode changes as follows:
Change on AIRFLOW (UP/DOWN) mode.
Left/right direction can be adjusted with the AIRFLOW
button the mode changes as follows:
Change on AIRFLOW (LEFT/RIGHT) mode.
NOTE
• The actual position of the flap and louver may differ from the display shown.
NOTE FOR HEATING OPERATION
• When operation starts, the flap and louver direction is fixed at the horizontal / center position in order to avoid cold draft, and return
to the set the position that was set after the warm air supply is starting.
• The flap and louver direction will be controlled to the horizontal/center position when the room temperature reaches the set tem-
perature and compressor stops or when defrosting is in operation.
• The airflow direction cannot be set during the period mentioned above. Change the airflow direction settings after the warm air is
supplied and the flap/louver goes to the set position.
MEMORY FLAP (FLAP OR LOUVER STOPPED)
When you press the AIRFLOW (UP/DOWN or LEFT/RIGHT) button once while the flap or
louver is operating, it stops swinging at the position. Since this angle is memorized in the
microcomputer, the flap or louver will automatically be set at this angle when the next opera-
tion is started.
• Do not expose directory to airflow from the air-conditioner for a long time.
• When in COOL or DRY operation, do not operate for a long period with the
airflow blowing straight down. Otherwise, condensation may appear on
the outlet grill and drip down.
• Do not try to adjust the flaps and louvers by hand, as the control angle may
change or the flap or louver may not be closed completely.
Multi-directional Air Flow (up/down air scroll and left/right air scroll)
Activating both up/down air swing and left/right air swing at the same time results in a multi-directional air flow.
Up/down air scroll
In COOL, DRY and FAN operation
Stops at this position
for 5 seconds.
Thick line
: moves quickly
Thin line
: moves slowly
Adjusting airflow direction
(Flap stopped)
(Louver stopped)
(Swing)
DANGER
CAUTION
In HEAT operation
Stops at this position
for 5 seconds.
(UP/DOWN) button on the remote control. Every time you press this
(LEFT/RIGHT) button on the remote control. Every time you press this
• Recommended angle of the flap when
stopping
COOL, DRY
Left/right air scroll
In COOL, DRY and FAN operation
Left louver
Right louver
– 10 –
(Swing)
HEAT
(Slant forward
blowing)
(Horizontal
blowing)
In HEAT operation