7.6.4 Operating times
TOTAL HRS
= This gives the actual hours that
REMAIN. HRS = This indicates how many remain
7.6.4.1 Total Hrs
To visualise the TOTAL HRS press the key
The total working hours of the stove will be
visualised.
To exit wait a few secons.
7.6.4.2 Remain Hrs
To visualise the REMAIN HRS press the key
The residual hours until the next special maintenance
will be visualised.
To exit wait a few seconds.
7.6.5 Remote device
After the installation of the remote device, it is
QHFHVVDU\ WKDW WKH ¿UVW VWDUWXS RI WKH VWRYH LV
performed from the command panel.
Upon reaching the room temperature set onto the
remote device, the stove will move to "STAND-BY
REMOTE".
Upon reaching the maximum and minimum
temperatures set on the remote device, the stove
will switch-off and restart automatically.
7.6.6 Room thermostat
After having connected the room thermostat
whenever it intervenes, the stove will move to the
¿UVW SRZHU OHYHO PLQLPXP RSHUDWLQJ OHYHO ZKLOH
maintaining the standard function unaltered.
The following message will appear on the display
"THERMOSTAT ON" or else the two temperature
YDOXHV ZLOO ÀDVK
7.6.7 PUFFER activation
The stove is also designed to heat an external
PUFFER.
To activate this function, proceed as follows:
-
disconnect the room sensor from the back of
the sove and position it inside the PUFFER.
-
on th control panel, press
simultaneously.
-
press "ON".
-
"ON" to activate the "PUFFER ON"
command.
cod. 00 477 1490 - 11/2013 - PN - Italy
USE AND MAINTENANCE
the stove has been operational
for the stove to operate at the
end of which extra-ordinary
maintenance is necessary; this
must be carried out by the TAC
(Technical Assistance Centre).
"ON" and
7.6.7.1 Changing commands from "SET ROOM
T" to "SET PUFFER"
Once you have completed the procedure for
activating the "SET PUFFER", all references to the
room temperature "SET ROOM T." and "ROOM
T." will be replaced by the water temperature of
the PUFFER.
On the control panel, the parameter "SET ROOM T."
is replaced by "SET PUFFER" and the parameter
"ROOM T." by "PUFFER T". The "t" indicates the
water temperature of the PUFFER.
7.6.8 Using the "SHORT" interface
7.6.8.1 OFF phase
.
OFF LV GLVSOD\HG RQ WKH ¿UVW OLQH RI WKH FRQWURO
panel and the work parameters on the second Fig.
7.6.8.1-1:
P =
POWER;
T
=
SET WATER T.
t
=
SET ROOM T / SET ROOM T
.
To change the prameter value you have to enter
the MENU SET WORK:
1) press the keys
2) press ON to enter the MENU SET WORK;
3) to change the parameters follow the procedures
described in paragraph 7.6.1.
7.6.8.2 Start phase
To switch the stove on keep the ON key pressed
for a few seconds.
The following message will appear onto the display
"WAIT FLAME".
This phase is automatic and is completely managed
by the stove. Consequently it is not possible to vary
any parameter (Fig. 7.3.2-1).
'XULQJ WKLV SKDVH WKH ÀDPH LV SURGXFHG DQG WKH
stove will reach the operating mode.
The following message will appear onto the display
"FLAME PRESENT".
The stove will automatically move onto the work
SKDVH LI WKH WHPSHUDWXUH LV VXI¿FLHQW WR RSHUDWH
correctly otherwise the NO IGNITION ALARM
ACTIVE will be signalled (par. 7.7.1).
7.6.8.3 Work Phase
Once alight, the word "WORK" appears on the
display, Fig.7.6.8.3-1.
The stove heats the room according to the work
parameters set.
7R DGMXVW WKH POWER and/or the SET WATER T.
and/or the SET ROOM T.:
1) press ON;
2) proceed, following the parameters from 2 to 4
in paragraph 7.6.1.
simultaneously;
61/172