7.7.4 Alarm DEPRESS
This occurs if there are anomalies concerning:
GUDXJKW LQ WKH VPRNH SLSH DQG KHQFH LQVXI¿FLHQW
pressure.
To restore the normal functioning of the stove reset
the alarm as indicated in paragraph 7.7.9.
If the alarm persists, see if the stove or smoke pipe
need servicing.
7.7.5 PELLET TEMP alarm (pellet temperature)
This happens when the pellet probe temperature
reaches an excessively high temperature.
To restore normal stove operation proceed as
follows:
1. wait until the stove is completely cold;
2. check that the ash box and hearth doors are
closed.
To restore the normal functioning of the stove reset
the alarm as indicated in paragraph 7.7.9.
7.7.6 SMOKE FAN alarm
This triggers if the smoke discharge fan is not
working properly.
To restore normal stove operation, follow the
procedure described in paragraph 7.7.9.
7.7.7 PELLET / SMOKE PROBE alarm
This alarm triggers when any one of the two
sensors malfunctions:
-
smoke probe
-
pellet probe
To restore normal stove operation, follow the
procedure described in paragraph 7.7.9.
7.7.8 Alarm BLACK OUT
This alarm triggers whenever there are malfunctions
concerning:
-
the electrical power is interrupted for long
periods of time;
-
lack of electrical power when the stove is
operating.
To restore normal stove operation, follow the
procedure described in paragraph 7.7.9.
7.7.9 Resetting the stove after alarm triggering
1. Await for the stove to be completely cooled
down and that the final cleaning cycle is
¿QLVKHG
2. Press the OFF key on the stove control panel
for 5 seconds;
3. The following message will appear onto the
display "Warning empty brasier".
4. Empty the hearth: the stove is now ready to be
turned on again.
If the alarm triggers again immediately after, call the
Palazzetti Technical Service Centre.
cod. 00 477 1490 - 11/2013 - PN - Italy
USE AND MAINTENANCE
7.8 CLEANING THE STOVE
This function is for cleaning the stove without
dispersing any of the ashes.
While this is being done, the smoke fan works at
maximum speed to prevent the ashes coming out
RI WKH ¿UHER[
The stove can only be turned on when it is completely
cold.
Press the OFF key for 2 seconds.
The smoke ventilator will start-up at the maximum
power.
,W ZLOO VWRS DXWRPDWLFDOO\ RQFH ¿QLVKHG
To interrupt the function press OFF.
63/172