Descargar Imprimir esta página

SATA filter 100 prep Instrucciones De Servicio página 249

Ocultar thumbs Ver también para filter 100 prep:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
<< Operating instructions SATA filter 100/101/103 prep >>
US
• Install the filter vertically on the wall with screws, thus ensuring full
functionality of the automatic condensate drain valve
• Connect air inlet G ½ i to compressed air line with detachable screw
connection
• Slide condensate drain hose [1-10] over the drain valve [1-9]; put
hose end into a suitable collection container (not included in delivery).
Note!
• Mount shut-off tap in front of the filter, e.g. Art. No. 10934 (not in-
cluded in delivery), allowing easy and safe filter maintenance.
7.2. Retrofit SATA filter 100 prep to filter 103 prep
[2]
For retrofitting with an activated charcoal filter, a SATA filter 101 prep [C]
(Art. No. 157412) is required:
• Depressurize filter (close shut-off tap)
• Loosen [2-1] air outlet module [D] from the dual-stage filter combina-
tion [A]/[B]
• Screw on [2-2] SATA filter 101 prep [C]
• Screw on [2-3] air outlet module [D]
8.
Use
Use solvent-resistant, antistatic, undamaged, technically flawless com-
pressed air hoses with a continuous pressure resistance of minimum 10
bar, e.g. Art. No. 53090!
Note!
• Install compressed air connection G ¼ i or appropriate SATA quick
coupling G ¼ i (Art. No. 13599, not included in delivery) to ball valve
[1-6].
• To ensure regular filter maintenance, please attach the adhesive stick-
ers 'filter exchange ' [1-7], [1-11], [1-13] in their respective colours
(yellow = sintered filter [A], blue = fine filter [B], black = activated
charcoal filter [C]) to the filter housings [1-8], [1-12].
XXVI.4
XXVI.4
Warning! Attention!

Publicidad

loading

Este manual también es adecuado para:

Filter 101 prepFilter 103 prep