• The indicator lamp ICE FULL turns off and a
few moments later ice cube production starts
again.
Indicator Lamp ADD WATER
The indicator lamp turns on if the water tank is
nearly empty and a beep tone sounds. Ice cube
production is automatically halted.
• Refill with potable water as described in chap-
ter "Making Ice Cubes".
• Press ON/OFF to resume making ice cubes;
the indicator lamp ADD WATER turns off.

Cleaning and Maintenance

WARNING:
Always disconnect from mains power supply
before cleaning.
CAUTION:
• Do not use harsh or abrasive cleaning agents.
• Do not use chemicals, acids, petrol or oil
products.
• Do not submerge the appliance in water.
NOTE:
• For hygienic reasons exchange the water in
the tank after 24 hours.
• To avoid fungi and bacteria leave the lid open
after use.
Ice Cube Container
Remove the ice cube container and clean it with a
mild detergent under running warm water.
Casing and Interior
• Clean casing and interior with a damp cloth.
• Use a diluted solution of vinegar and water.
Drain Residual Water
Drain the residual water if the appliance is not in
use for a longer period of time.
• Put the ice cube maker e.g. into the sink.
• Pull the plug at the bottom of the water tank.
38
• Do not forget to replace the plug after the water
has drained out.

Troubleshooting

Problem
Possible
Cause
No function.
No power
supply.
Compressor
Mains power
noisy.
supply too low.
Indicator lamp
Water level too
ADD WATER
low.
flashes.
Indicator lamps
No power
do not turn on.
supply.
Ice cubes are
Water tempera-
too large and
ture or ambient
stick together.
temperature too
low.
Indicator lamps
Water tank is
ICE FULL and
blocked by ice
ADD WATER
cubes.
light up at the
same time.
Solution
Check the wall
outlet with a
different appli-
ance; connect
the plug prop-
erly to the wall
outlet.
Turn the
appliance off
and check the
mains power
supply.
Refill water
" Making Ice
Cubes ".
Connect to
mains power
supply.
Check fuse.
Applicance
defective.
Use warmed
water.
Disconnect
from mains
power supply.
Remove the
ice cubes from
the automatic
scoop. Recon-
nect and press
ON/OFF.