FAULT CODES
F1
Voltage fault
F2
Ventilation fault
F3
Compressor does not start
F4
Compressor speed fault
F5
Temperature sensor fault
E0
Sensor defective
E1
Short circuit on the sensor
Note: If there are faults, first always check whether the appliance is connected to a
suitable battery. Then wait 3 minutes before switching the appliance back on. If the
fault still occurs, contact our customer service organisation.
OPERATION
1.
You can operate the appliance with the AC power cord at 100 - 240 V~/50 -
60 Hz or alternatively with the 12 V DC power cord at 12 V~ DC/24 V.
2.
When connected to a 12 V outlet, the appliance will not operate at voltages
below 9.6 V. The appliance will not operate until the voltage reaches 12.2 V
or higher.
3.
When connected to a 24 V power outlet, the appliance will not operate if
the voltage is less than 21.3 V. The appliance only works from a voltage of
25.2 V or higher.
4.
Plug one end of the power cord into the socket on the appliance and the
other end into the electrical outlet. Make sure that you are using the correct
power cord.
5.
Switch on the appliance via the ON/OFF switch.
6.
After the appliance is switched on, you can select the temperature from
-18 °C to +20 °C. The temperature can be selected from -18 °C to +20 °C.