Operating mode with a room sensor provided as standard

If the room sensor provided as standard is used, the display will show the room temperature.
To set the desired temperature (room temperature set point change): briefly press the P4 key to enter the corresponding section and
use the P4 and P5 keys to adjust the desired value. When this value is reached, MODULA WORK is shown on the display; in this case,
the thermo-stove minimises the consumption of pellets by decreasing the heating power.

Operating mode with an external thermostat

If an external thermostat properly connected to the board (as shown in the electrical diagrams on pages 32 and 33) is used, the display
will no longer show the room temperature, but T ON (WHEN THE CONTACT IS CLOSED), or T OFF (WHEN THE CONTACT IS OPEN).
! IMPORTANT
Room temperature can be directly adjusted from the wall-mounted thermostat. When the set temperature is reached, MODULA WORK is
shown on the remote control display; in this case, the thermo-stove minimises the consumption of pellets by bringing the heating power to a
minimum. If COMFORT CLIMATE mode is active, the thermo-stove will automatically switch off and restart (for details see paragraph 9.3).
N.PEL.
N.H2O
N.ROOM
Please note: If you want to use COMFORT CLIMATE, an external thermostat with OFF-SET of at least 3 °C
is advisable.

Air ventilation adjustment

To change the ventilation speed, perform these operations starting from the main menu status:

1. Press and hold the P6 key for 2 seconds until the following screen appears.
V5
FANS
2. Use the P4 and P5 keys to change the ventilation speed.
Ventilation can be switched off (OFF), adjusted from V1 (minimum speed) to V5 (maximum speed), or be set to AUTO mode following the
stove power.
3. To return to the home screen just press P3.

Changing the boiler water temperature

To change the boiler water temperature set point, press the P5 key to access the corresponding menu and use the P4 and P5 keys
to adjust the value.

Setting the pellet-air mixture

Setting the pellet-air mixture allows you to easily adjust the
suction of fumes and the amount of pellets loaded. This
makes it possible to adjust combustion depending on the
thermo-stove draught and pellet hardness. Press the P6 and
P7 simultaneously to access the setting and to display the
following strings;
2
PELLETS
- 3
DRAUGHT
Model Rodi Steel Use and Maintenance Manual
TO ENABLE THE EXTERNAL THERMOSTAT, PRESS KEY P4 AND THEN REPEATEDLY KEY P1 TO
REACH THE "EST" VALUE ON THE DISPLAY; CONFIRM WITH KEY P7.
THERM.
-TC1+
Red
Blue
Black
Black
Active ventilation indication
N.ROOM
THERM.
1
2
3
4
5
6
7
ROOM
EXTERNAL
SENSOR
THERMOSTAT
0
PELLETS
0
DRAUGHT
Draught values can be changed via the P6 and P7 keys,
whereas the amount of pellets used (the value indicated
during change only reports a percentage value affecting
the default parameters set on the electronic board) can be
dosed via P4 and P5.
Rev.2 31/07/2017
Page70
-TC1+
8
9
10
SMOKE