INSTALLATION

Installing/Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 1000° C.
For the installation, you need one of the following lamps:
GE CP24 230V/1000W GX-9,5 250h
OMNILUX 230V/1000W GX-9,5 200h 3200K
PHILIPS 6995P 230V/1000W GX-9,5 200h
GE T19 240V/1000W GX-9,5 750h Longlife
OMNILUX 230V/1000W GX-9,5 750h
PHILIPS 6996P T19 230V/1000W GX-9,5
GE T11 240V/1000W GX-9,5 750h 3050K
GE CP70 FVB 240V/1000W GX-9,5 3200K
PHILIPS 6984P 230V/1000W GX-9,5
OMNILUX 230V/1000W GX-9,5 Roundlux
Procedure:
Step 1: Unscrew the fixation-screws of the lamp protection-cover.
Step 2: Remove the protection-cover.
Step 3: If replacing the lamp, remove the old lamp from the socket.
Step 4: Insert the 230V/1000W GX-9.5 lamp into the lamp-socket.
Step 5: Replace the protection-cover and tighten the screws.
Mount the SL-1200 on the stand.

DANGER TO LIFE!

Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
No. 88344000
No. 88344005
No. 88344015
No. 88344100
No. 88344105
No. 88344115
No. 88344200
No. 88344300
No. 88345015
No. 88346005
Do not operate this device with opened protection-cover!
15/33
41908360_V_1_1_2643.DOC