Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 115
Operating Instructions SATAminijet 3000 B HVLP, minijet 3000 B T HVLP
US
• Never use ultrasonic cleaning devices - leads to damage of
nozzle set and gun surface!
• After cleaning, the spray gun, the material passages, the air
cap including thread as well as the gravity flow cup have to
be blown dry with clean compressed air!*
* otherwise risk of corrosion
• Check spray pattern after cleaning the nozzle set!
• Further cleaning tips can be found at www.sata.com/TV.
9.

Maintenance

• Prior to maintenance, disconnect spray gun from the compressed air
circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
9.1. Replacing the Nozzle Set
and [7-6]
Every SATA nozzle set consists of "paint needle" [7-1], "air cap" [7-2]
and "fluid tip" [7-3] and has been hand-adjusted to provide a perfect
spray pattern. Therefore, always exchange the complete nozzle set. After
installation, please adjust material flow according to chapter 7.2.
9.2. Replacing the Air Distribution Ring Steps:
[7-2], [7-3], [8-1], [8-2] [8-3], [7-4], [7-5] and [7-6]
• Remove air distribution ring with SATA extraction tool only.
• Do not apply force to avoid damage of sealing surfaces.
410
Warning! Attention!
Information!
Warning! Attention!
Notice!
[7-1], [7-2], [7-3], [7-4], [7-5]
[7-1],

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Minijet 3000 b t hvlp

Tabla de contenido