STORAGE

The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.

Generator Storage

• Clean the generator as outlined in "To Clean the
Generator."
• Check that cooling air slots and openings on generator
are open and unobstructed.
WARNING
Storage covers can be flammable.
• DO NOT place a storage cover over a hot generator.
• Let equipment cool for a sufficient time before placing the
cover on the equipment.

Engine Storage

See engine operator's manual for instructions.

Other Storage Tips

• Always store unit with fuel shut off valve in the "Off"
position (Figure 5, earlier).
• To prevent gum from forming in fuel system or on
essential carburetor parts, empty entire contents of both
supplied fuel stabilizer containers into fuel tank and fill
with fresh fuel. Run the unit for several minutes to
circulate the additive through the carburetor.The unit
and fuel can then be stored for up to 24 months.
Additional fuel stabilizer can be purchased locally.
• Fuel tank may swell in storage if vent is closed.When
storing generator with fuel in the tank, make sure the
vent knob is turned fully counter-clockwise.
• Store unit in clean and dry area.
14