6.2

Attaching the position controller

Danger of injury!
Electrical fields from adjacent devices influence the function
of the position controller and may cause uncontrolled
cylinder movements.
O
Make sure that the position controller is operated outside
of any interfering electrical fields that are stronger than
those listed in the technical data.
Any mounting orientation may be used with the position
controller. Depending on the version, you can mount the device
on a plate or wall or in a control cabinet or 19" unit.
1. Attach the position controller at the desired location in the
housing with four M4 screws.
2. Mount the position controller as a 19" assembly in your
19" unit.
6.3

Connecting the position controller

Danger of fire caused by incorrect wiring!
A short circuit could result in a fire.
O
Check that the wiring is correct before commissioning.
Always use shielded cables for the set and actual value
connections. This will help to avoid interference by
electrical fields.
Connect the position controller in accordance with the following
table.