N o s e A s s e m b l i e s
S t e m D e f l e c t o r
The stem deflector is a very simple alternative to the standard stem
collector and allows access in restricted areas. To replace the stem
collector with the stem deflector proceed as follows:
•
Unscrew retaining nut 21 by inserting a 3 millimetre diameter rod
into one of the holes.
•
Remove retaining nut 21 and the stem collector assembly, items
15, 16, 17, 18, 19, and 20.
•
Screw the adaptor nut onto end cap 22.
•
Push the boss end of the stem deflector into the internal groove
of the adaptor nut.
•
Rotate the stem deflector until the aperture faces away from the
operator and other person(s) in the vicinity.
E x t e n s i o n
Fitted between the tool and the nose assembly, the extension allows
access into deep channels.
•
To fit the extension, remove any nose assembly components.
•
Screw the inner extension to jaw spreader housing 1.
•
Screw the outer onto head assembly 4.
•
Fit the nose assembly onto the extension.
Item numbers in bold refer to the general assembly drawing and parts list on pages 16-17.
10
STEM DEFLECTOR
ADAPTOR NUT
71210-20101
STEM DEFLECTOR: 71210-20100
INNER
71210-20301
EXTENSION: 71210-20300
07340-00342
OUTER
71210-20302