INSTALLATION
NOTICE
Do not modify wiring or cut thermostat capillary wire on
control box to increase remote mounting distance. Cutting
thermostat capillary wire will cause unit to overheat and
may damage unit as well as surrounding countertop.
NOTE: The remote control box should be mounted using
screws with a 1/4" (6 mm) minimum diameter screw
head inserted through the keyholes located on the
mounting brackets. The remote control box is to be
readily removable, not permanently mounted.
Model
Minimum Width
HBGB-2418
629 mm (24-3/4")
HBGB-3018
781 mm (30-3/4")
HBGB-3618
933 mm (36-3/4")
HBGB-4818
1238 mm (48-3/4")
HBGB-6018
1543 mm (60-3/4")
HBGB-7218
1848 mm (72-3/4")
Countertop Cutout
Maximum Width
635 mm (25")
787 mm (31")
940 mm (37")
1245 mm (49")
1549 mm (61")
1854 mm (73")
Trim Mounting Ring
Metallic
Countertop
Figure 8. HBGB Countertop Installation
8. Once all components are secured, proceed to the
OPERATION section.
NOTE: A 1829 mm (6') cord is supplied with this appliance; any
excess cord should be neatly routed so it does not hang
down.
Minimum Depth
476 mm (18-3/4")
476 mm (18-3/4")
476 mm (18-3/4")
476 mm (18-3/4")
476 mm (18-3/4")
476 mm (18-3/4")
Apply a bead of NSF-approved
sealant between the metallic
countertop and trim mounting ring.
Sealant must be rated for use at
a minimum temperature of
121°C (250°F).