Gas Operation (Liquid Gas); Explanation Of Operating Controls - Dometic RM 8400 Instrucciones De Uso

Ocultar thumbs Ver también para RM 8400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 91
Refrigerator operation
Mains power (230V)
CAUTION!
This option should only be selected where
the supply voltage of the connection for
power supply corresponds to the value
specified on the data plate. Any difference
in
values may result in damage the
appliance.
4.4

Gas operation (liquid gas)

n
The refrigerator must be operated using
liquid gas (propane, butane) (no natural gas
or town gas).
n
When using LPG gas, please consider that
the burner needs cleaning at shorter inter-
vals due to the gas combustion method (2
- 3 times per year recommended.
n
In Europe, gas operation is permitted while
travelling only on the condition that the gas
system of the vehicle is equipped with a
hose rupture protection. The national regu-
lations of the respective country must be
observed.
n
For physical reasons, gas ignition faults
could occur starting from an altitude above
sea level of approx. 3280 ft. / 1000 m (No
malfunction!)
n
On the initial refrigerator start-up or after a
cylinder change, air may be trapped in the
gas line. To purge the air from the lines,
switch on the refrigerator and any other gas
appliances (e.g. stove) for a short time. The
gas ignites without delay.
n
Each refrigerator with manual ignition is
equipped with an automatic flame safety
valve which interrupts the gas supply auto-
matically after approx. 30 seconds when
the flame has extinguished.
WARNING!
As a basic rule, gas operation is prohibi-
ted in petrol stations!
Prior to starting the refrigerator in gas
mode :
n
Open the gas cylinder valve.
n
Open the shut-off valve for gas supply to
the refrigerator.
4.5
Explanation of operating
controls
NOTE!
Manual energy selection / manual ignition
battery igniter (RM 8xx0) :
1
1
= Power On switch / Energy selector switch
2
2
= Temperature controller
3
= Battery igniter (gas)
3
4
= Flame indicator (galvanometer)
4
1
2
16
OFF
230VAC
12VDC
Gas
Fig. 6
3
4
Fig. 7