GrillMaster 720-0783 Manual Del Usuario página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

!
Never lean over the grill cooking area while
lighting your gas grill. Keep your face and body a
safe distance (at least 18 inches) from the
cooking grid surface when lighting your grill by
match.
Manually Lighting Your Grill by Match
1. Insert a match into the manual lighting stick.
2. Follow steps 1 through 9 of the Lighting
instructions on page 20.
3. Light the match and extend the lighting stick to
cooking grid surface.
4. Turn the desired control knob to the HIGH
position setting to release gas. The burner
should light immediately.
OFF
IGNITE / HIGH
LOW
!
Should a "FLASH-BACK" fire occur in/or
around the burner tubes, follow the
instructions below. Failure to comply with
these instructions could result in a fire or
explosion that could cause serious bodily
injury, death, or property damage.
Shut off gas supply to the gas grill.
Turn the control knobs to OFF position.
Put out any flame with a proper fire
extinguisher.
Open grill lid.
Once the grill has cooled down, clean the
burner tubes and burners according to the
cleaning instructions found on page 22.
WARNING
WARNING
If Grill Still Fails To Light
1. Check gas supply and connections for leaks.
Check that all wire connections are secure.
2. Repeat basic lighting procedure. If your grill still
fails to operate, turn the gas off at source, turn
the control knobs to OFF, then check the
following:
Misalignment of burner tubes over orifices
Correction: Reposition burner tubes over
orifices.
Plugged orifice
Correction: Remove burners from grill,
carefully lift each burner up and away from gas
valve orifice. Remove the orifice from gas valve
and gently clear any obstruction with a fine wire.
Then reinstall all orifices, burners, and cooking
components.
3. If an obstruction is suspected in grill burner
valves, please call for repair service at 1-800-
648-5864.
4. If the grill still does not light you may need to
purge air from the gas line or reset the pressure
purge air from the gas line or reset the pressure
regulator excess gas flow device. Note: This
procedure should be done every time a new LP
gas tank is connected to your grill.
To purge air from your gas line and/or reset the
pressure regulator excess gas flow device:
Turn all control knobs to the OFF position.
Turn off the gas at the tank valve.
Disconnect pressure regulator from LP gas tank.
Let unit stand for 5 minutes.
Reconnect pressure regulator to the LP gas tank.
Turn the tank valve on slowly until ¼ to ½ open.
Open the grill lid.
Push and turn any control knob to HIGH.
Turn control knobs to HIGH until all the burners
are lit.
You may start to use the grill.
5. If all checks or corrections have been made and
you still have questions about operating your
gas grill, call the Grill Information Center at
1-800-648-5864
21