Acceleration Deceleration
curve
Power
consumption
brake
Brake
DC brake
jog
Multi-section speed run
Inbuilt PID controller
Automatic energy saving
run
Automatic voltage
regulate (AVR)
Automatic current limiting Current limited automatically under run mode in avoid of
carrier modulation
Speed tracking restart
running command
specified channel
Running frequency
specified channel
Binding function
Digital input channel
Analog input channel
Pulse ouput channel
Two modes: straight line acceleration and deceleration; S curve
acceleration and deceleration; 15 kinds of acceleration and
deceleration time, time unit (0.01s,0.1s,1s) for option , max. time
for 1000 minutes.
15KW & under power range with inbuilt brake unit, only add
brake resistor between (+)and PB.
18.5KW & up power range is possible to add brake unit
between (+)and (-)outside.
Start, stop action for option, action frequency 0~15Hz, action
current 0~100% of rated current, action time 0~30.0s
Jog frequency range: 0Hz~up limit frequency;
Jog acceleration and deceleration time 0.1~6000.0 for setting.
Realized by inbuilt PLC or control terminal; with 15 section
speed, each section speed with separately acceleration and
deceleration time; with inbuilt PLC can achieve reserve when
power down.
Convenient to make closed-loop control system
Optimize V/F curve automatically to achieve power saving run
according to the load status.
Automatically keep output voltage constant, when the power
grid voltage changes
inverter over-current frequently to trip.
Modulate carrier wave automatically according to the load
characteristic.
Make rotating motor smoothly start without shocking
Keypad specified, control terminal specified, communication
specified can switch through various means.
Main & auxiliary specified to a realize one main adjusting
and one fine control. Digital specified, analog specified, pulse
specified, pulse width specified, communication specified and
others, which can be switched by many means at any time.
Run command channel and frequency specified channel can
bind together randomly and switch synchronously
Channel 8 for universal digital input, max. Frequency 1KHz,
channel 1 can be used as pulse input channel, max. Input
50KHz, which can be expanded to channel 14.
Channel 2 for analog input channel, AI1 can choose 4~20mA
or 0~10V output, AI2 is differential input channel, 4~20mA or
-10~10V for option, which can be expanded to channel 4 analog
input.
0.1~20KHz pulse square signal output to achieve setting
frequency, output frequency and other physical quantity output.
2. Inverter Type and Specification
129