Protection grade
Cooling mode
Installation mode
Para obtener un funcionamiento perfecto del variador, compruebe
y seleccione el tipo correcto de acuerdo con este capítulo antes del
cableado
Es necesario seleccionar el tipo correcto de modelo, de lo contrario
puede causar un funcionamiento anormal del motor o daños en el
3. Installation and wiring
3.1. Installation ambient
3.1.1. The demands for installation ambient
01.
Installed in drafty indoor place, the ambient temperature should be within-
10ºC~40ºC, it needs external compulsory heat sink or reduce the volume
if temperature is over than 40ºC; when temperature under -10ºC, please
preheat inverter fi rst.
02.
Avoid installing in places with direct sunlight, much dust, fl oating fi ber
and metal powder.
03.
Don't install in place with corrosive, explosive gas.
04.
The humidity should be smaller than 95%RH, without condensation water.
05.
Installed in place of plane fi xing vibration smaller than 5.9m/s²(0.6g).
06.
Keep away from electromagnetic disturbance source and other electronic
apparatus sensible to electromagnetic disturbance.
3.1.2. Installation direction and space
01.
Normally the inverter should be mounted vertically, horizontal mounting
will seriously affect heat dissipation and the inverter must be used in lower
volume.
02.
Demand for minimum mounting space and distance, please see Fig.3-1.
03.
When installing multiple inverters up and down, leading divider must be
applied between them, see Fig. 3-2.
IP20
Fan
Wall hanging type
3. Installation and wiring
131