F00.06
C-05 display
parameter selection
when operation
F00.07
C-00 display
parameter selection
when stop
F00.08
C-01 display
parameter selection
when stop
F00.09
C-02 display
parameter selection
when stop
F00.10
C-03 display
parameter selection
when stop
F00.11
C-04 display
parameter selection
when stop
F00.12
C-05 display
parameter selection
when stop
F00.13
Power-on fault
monitor parameter
selection
F00.14
Parameter
operation control
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
0~5
units digit: Parameter modification
operations
0: All parameters are allowed to be modified
1:Except current parameter, all other
parameters are not allowed to modify the
2:ExceptF01.01,F01.04and current
parameter, all other parameters are not
allowed to be modified
tens digit: Reset to factory defaults
0:No action.
1:All parameters return to default.(not
include fault record parameter group(F26
group) parameter).
2:Except for motor parameter: all parameters
return to default.(not include F15 and F26
group parameter).
3:Extension parameter return to default.(only
F21~F24 group parameter return to default).
4:Virtual parameter return to default.(only
F20 group parameter return to default).
6. Function parameter schedule graph
1
9
1
2
1
6
1
48
1
14
1
20
1
9
1
0
1
000
o
o
o
o
o
o
o
o
×
169