F01.05
Auxiliary frequency
digital
control
F01.06
Main and
auxiliary provide
calculating setup
F01.07
Auxiliary frequency
provide coefficient
F01.08
Coefficient after
complex of main
and auxiliary
frequency
F01.09
Auxiliary frequency
range selection
F01.10
Auxiliary frequency
source scope
F01.11
upper limit
frequency
F01.12
Low limit
frequency
F01.13
Low limit
frequency run
mode
F01.14
Sleep run
hysteresis
frequency
F01.15
Run command
channel selection
. units digit: power down reserve setup
0:Auxiliary frequency power down reserve.
1:Auxiliary frequency power down no
reserve.
. tens digit: halt reserve setup
0:Halt auxiliary frequency hold.
1:Halt auxiliary frequency recovery
parameter F01.04
0: Main frequency (complex frequency of current is
main frequency).
1: Auxiliary frequency(complex frequency of current is
auxiliary frequency.)
2: Plus(polarity oppose of complex and main
frequency, complex frequency is zero).
3: Minus(polarity oppose of complex and auxiliary
frequency, complex frequency is zero).
4: Multiplication(polarity opposed of main and auxiliary
frequency: complex frequency is zero).
5: Max(the max frequency of main and auxiliary
absolute value).
6: Min(the min frequency of main and auxiliary
absolute value).
7: Selection no-zero value(auxiliary is not negative,
main frequency prior; auxiliary is negative, complex
frequency is zero).
0.00~10.00
0.00~10.00
0: Relative upper limit frequency.
1: Relative main frequency.
0.00~1.00
low limit frequency~600.00Hz
0.00Hz~upper limit frequency
0: As low limit frequency run.
1: As setting frequency run.
2: As zero frequency run.
3: Sleep: PWM clocked at sleep mode.
0.01Hz~upper limit frequency (This function can be
used to finish the sleep mode function, realizing energy-
saving operation process, and the hysteresis width can
avoid inverter starting frequently in threshold)
0: Operation keyboard run control.
1: Terminal run command control
2: Communication run command control.
6. Function parameter schedule graph
1
1
0.01
0.01
1
0.01
0.01Hz
0.01Hz
1
0.01Hz
1
11
o
0
o
1.00
o
1.00
o
0
o
1.00
o
50.00Hz
×
0.40Hz
×
2
×
0.01Hz
o
0
o
173