F17.08
MPPT Low limit
Frequency
F17.09
MPPT Mode Function
F17.10
Wakeup delay time
F17.11
~
Reserved
F17.20
Function
Name
code
F18.00
Operation panel control
frequency binding
F18.01
Terminal control
frequency binding
F18.02
Communication
control frequency
binding
F18.03
Digital frequency
integral function
selection
F18.04
Keyboard UP/DW
integral rate
F18.05
Keyboard no integral
single step's size setup
F18.06
Terminal UP/DW
integral rate
F18.07
Terminal no integral
single step's size setup
F18.08
Droop control decline
frequency
F18.09
Setup accumulate
power on time
Range: 0.00Hz ~ Upper limit Frequency
Range: 0 ~ 1
0.0~6000.0s
F18-Enhance Control Parameter Group
Set Range
0:no binding
1:operation keyboard digital setup
2:AI1 analog setup
3:AI2 analog setup
4:terminal UP/DOWN adjusting setup
5:communication provide(Modbus and
external bus use the same main
frequency storage)
6:EAI1 analog setup(extension valid)
7:EAI2 analog setup(extension valid)
8:high speed pulse setup( X8 terminal
need choose the relative function)
9:terminal pulse width setup(X8 terminal
need choose the relative function)
10:terminal encoder provide(decide by
X1, X2)
11~15: Reserved
Same as above
Same as above
. units digit: keyboard UP/DW integral control
0:integral function
1:no integral function
. tens digit: terminal UP/DW integral control
0:integral function
1:no integral function
0.01~50.00Hz
0.01~10.00Hz
0.01~50.00Hz
0.01~10.00Hz
0.00~10.00Hz
0~65535 hours
6. Function parameter schedule graph
0.01Hz
10.0Hz
1
0.1s
Min.
Factory
Unit
Default
1
1
1
1
0.01Hz
0.10Hz
0.01Hz
0.01Hz
0.01Hz
0.20Hz
0.01Hz
0.10Hz
0.01Hz
0.00Hz
1
×
0
×
0.0s
o
Modifi
-cation
0
o
0
o
0
o
00
o
o
o
o
o
o
0
o
199