7.2. Failure record lookup
This series inverter can record latest 4 failure code and inverter run parameter
of the last 2 times failure, refer to these information can redound to finding out
reason of the failure.
Failure information is all stored in F26 group parameter, please enter into F26
group parameter to see about information by referring to keypad operation
method.
Code
Previous one failure record
F26.00
Previous two failure record
F26.01
Previous three failure record
F26.02
Previous four failure record
F26.03
Set freq. at previous failure
F26.04
Output freq. at previous failure
F26.05
Output current at previous failure
F26.06
DC bus volt. at previous failure
F26.07
Module temp. at previous failure
F26.08
Content
Code
Input terminal state at previous failure
F26.09
Accumulated running time at previous
F26.10
failure
set freq. at previous 2 failure
F26.11
output freq. at previous 2 failure
F26.12
Output current at previous 2 failure
F26.13
DC bus volt. at previous 2 failure
F26.14
Module temp. at previous 2 failure
F26.15
Input terminal state of previous 2 failure
F26.16
Accumulated running time of previous
F26.17
2 failure