Tds600 Solar Pump Inverter Special Parameters Graph - toscano TDS600 Serie Manual De Usuario

Ocultar thumbs Ver también para TDS600 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. TDS600 solar pump inverter special parameters graph

For Solar pump application, there are two modes CVT mode and MPPT mode
for choose.
a. CVT mode: Set;
F11.00=1(PID Close-loop valid)
F11.01=9(Choose F12.14 as CVT targetvoltage)
F11.02=9(Choose DC BUS voltage as feedback)
F11.13=1
F19.32=0200
When DC BUS voltage lower than the value of F17.07 (Sleep DC voltage), the
inverter will come into Sleep mode. When DC Bus voltage higher than F17.06
(Wakeup DC voltage) and lasts F17.10 (Wakeup delay time), the inverter will
wake up and start to work again.
b. MPPT mode: Set;
F17.09=1 MPPT Mode Function.
F01.00=11 MPPT function enabled.
Please adjust F17.06, F17.07, F17.08 and F17.10 properly to get suitable
effect. Water upper limit level and Water low limit level functions available for
CVT mode and MPPT mode, please refer to #72 and #73 functions for multi-
input function terminal at F8 parameters Group.
226

Hide quick links:

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido