Ferroli ECONCEPT 51 A Instrucciones De Uso página 39

Ocultar thumbs Ver también para ECONCEPT 51 A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ECONCEPT 51 A
Turning the boiler off
Press the button
(detail 7 - fig. 1) for 5 seconds.
fig. 5 - Turning the boiler off
When the boiler is turned off, the PCB is still powered.
Domestic hot water (with optional hot water tank installed) and heating operation are dis-
abled. The antifreeze system remains activated.
To relight the boiler, press the button
The boiler will be immediately ready to operate whenever domestic hot water is drawn
(with optional hot water tank installed) or in case of a room thermostat demand.
To completely disconnect the power to the unit, press the button detail 14 fig. 1.
B
The antifreeze system does not work when the power and/or gas to the unit are
turned off. To avoid damage caused by freezing during long idle periods in win-
ter, it is advisable to drain all water from the boiler, DHW circuit and system; or
drain just the DHW circuit and add a suitable antifreeze to the heating system,
complying with that prescribed in sec. 3.3.
2.4 Adjustments
Summer/Winter Switchover
Press the button
detail 6 - fig. 1 for 1 second.
The display activates the Summer symbol detail 10 - fig. 1. The heating function is deac-
tivated, whereas the possible production of domestic hot water (with optional external hot
water tank) remains activated. The antifreeze system remains activated.
To deactivate Summer mode, press the button
ond.
Heating temperature adjustment
Use the heating buttons
ture from a min. of 20°C to a max. of 90°C.
eco
reset
comfort
(detail 7 fig. 1) again for 5 seconds.
eco
reset
comfort
fig. 6
eco
reset
comfort
fig. 7
(detail 6 - fig. 1) again for 1 sec-
(details 3 and 4 - fig. 1) to adjust the tempera-
eco
reset
comfort
fig. 8
cod. 3540S560 - 03/2009 (Rev. 00)
DHW temperature adjustment (with optional hot water tank installed)
Use the DHW buttons
from a min. of 10°C to a max. of 65°C.
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature required in the rooms.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the temperature desired in the rooms. The boiler unit
will set the system water according to the required room temperature. For information on
the remote timer control, please refer to its user's manual.
Sliding Temperature
When the optional external probe is installed the corresponding symbol (detail 22 fig. 1)
is activated on the control panel display (detail 5 - fig. 1). The boiler control system op-
erates with "Sliding Temperature". In this mode, the heating system temperature is con-
trolled according to the outside weather conditions, in order to ensure high comfort and
energy saving throughout the year. In particular, the system delivery temperature is de-
creased as the outside temperature increases, according to a specific "compensation
curve".
With Sliding Temperature adjustment, the temperature set with the heating buttons
(details 3 and 4 - fig. 1) becomes the maximum system delivery temper-
ature. It is advisable to set a maximum value to allow system adjustment throughout its
useful operating range.
The boiler must be adjusted at the time of installation by qualified personnel. Possible
adjustments can in any case be made by the user to improve comfort.
Compensation curve and curve offset
reset
Press the button
(detail 8 - fig. 1) for 5 seconds, to display the actual com-
pensation curve (fig. 10) which can be modified with the DHW buttons
(details 1 and 2 - fig. 1).
Adjust the required curve from 1 to 10 according to the characteristic (fig. 12).
By setting the curve to 0, sliding temperature adjustment is disabled.
fig. 10 - Compensation curve
Press the heating buttons
curve offset (fig. 13), modifiable with the DHW buttons
- fig. 1).
fig. 11 - Curve parallel offset
reset
Press the button
(detail 8 - fig. 1) again for 5 seconds to exit parallel curve
adjustment mode.
(details 1 and 2 - fig. 1) to adjust the temperature
eco
reset
comfort
fig. 9
I
eco
reset
comfort
(details 3 and 4 - fig. 1) to access parallel
(details 1 and 2
eco
reset
comfort
EN
39

Publicidad

Tabla de contenido
loading

Tabla de contenido