This item checks the ISDN interface.
B R I M I S C
D I A G R E Q U E S T : [. . . . . . . . . . . .]
I N F O 1 S I G N A L S
L O O P B A C K : [ O F F
L O C A L R E Q U E S T
R E M O T E R E Q U E S T
O F F R E Q U E S T
< E X I T >
DIAG REQUEST:
You can check the BRI interface software version.
This item is only for checking.
Press ENTER.
The BRI software version number is displayed in the
DIAG REQUEST box.
INFO1 SIGNALS
Press ENTER.
The INFO 1 signal generates and Layer 1 test starts.
LOOP BACK
You can loop back the primitive of the request
between the local and remote sites for another testing
purpose.
Select LOCAL REQUEST, REMOTE REQUEST or
OFF REQUEST using V or v, then press ENTER.
Loop back starts.
Note
You have to turn the Monitoring Codecs off and on at
both sites for the next communication after executing
REMOTE REQUEST.
To cancel the diagnostics
Move the cursor to <EXIT> and press ENTER.
Diagnostics are canceled and the DIAL LIST menu
appears.
]

FACTORY SETUP

Initializes the system to the factory-setting.
The system asks you to initialize. To initialize the
system, move the cursor to <OK> and press ENTER.
The DIAL LIST menu appears.
Chapter 2 Setup Using the SETTING Menu
2-19
(GB)