Control units CP.K3-RE / CP.K3-RI / CP.K4-RE / CP.K4-RI
Control units for 24Vdc motors with powers under 120W.
a) The electrical installation and operating logic must comply with statutory regulations.
b) Cables of different voltages must be physically separated or otherwise adequately screened with
secondary insulation of at least 1 mm.
c) Cables must be secured by additional clamps next to their terminals.
d) Control all wiring connections are correct before powering.
e) Check the Dip-Switch settings are correct.
f) Unused N.C. inputs must be jumpered.
Terminals
Function
1-2
Power
4-5
24Vdc motor
6-7
Beacon
8-9
24 Vac
10-11
SCA
12
COM
13
STOP
14
PHOT
15
OPEN
16
CLOSE
17
PP Step-by-step Step-by-step button input (N.O. contact)
18
COM
19
SWO
20
SWC
21
SWO-R
22
SWC-R
24-25
Antenna
26-27
EDGE
J2
Radio receiver
VAUX-0-VMOT
Secondary
L1-N1
Primary

GENERAL RULES

INPUT/OUTPUT FUNCTIONS
Description
230Vac 50Hz input (1-Neutral/2-Live)
24Vdc motor connection
24Vac max 40W beacon connection
24Vac/max 0.5A accessory power connection
24 Vac connection for gate open light – max 3W
Common for all control signal inputs.
STOP button input (N.C. contact)
Safety input, N.C. contact (e.g. photocells)
During closing: when the contact opens the motor is stopped and
the stroke direction is reversed immediately (i.e. opening).
During opening: disabled.
OPEN button input (N.O. contact)
CLOSE button input (N.O. contact)
Common connection for travel limit switches.
OPEN travel limit switch input (N.C. contact).
CLOSE travel limit switch input (N.C. contact). When the SWC limit
switch trips the motor continues running for 1.5 sec (with no Prox-
imity signal) to make sure the gate is firmly shut.
Open slowdown travel limit switch input (N.C. contact).
When this contact opens it starts the open slowdown cycle.
Close slowdown travel limit switch input (N.C. contact).
When this contact opens it starts the close slowdown cycle.
Plug-in radio receiver antenna board connections
(24-signal/25-screen).
Edge contact input
Electric edge: Jumper "DAS" bridged
Mechanical edge: Jumper "DAS" open
If the edge trips during opening the gate stops. If the gate is clos-
ing it will change direction to open for 3 sec.
Edge not used: Jumper "DAS" open and jumper across terminals
26-27.
Socket for two channel radio receiver ("RE" versions)
The RI versions have a built-in radio receiver
Terminal for secondary circuit of transformer
Terminal for primary circuit of transformer