INSTALL THE
DUCTWORK
(This section for 40000 and 42000 hoods only. 41000
hoods skip this section and go on to "Install
Range
Hood'.')
NOTE
These
instructions
will follow
plans made
on
Page 2. Start at the exterior
and run ductwork
back to the range hood.
For best possible
performance,
use the short-
est possible
duct run and a minimum
number
of elbows. Do not vent a range hood into an at-
tic space. A buildup
of grease in the attic could
become
a fire hazard.
Use only metal ductwork.
DO NOT USE PLAS-
TIC DUCT. Assemble
duct run securely
so that
in case of a grease
fire on the range,
the fire
will be contained
inside
metal ductwork.
Tape all duct connections.
1. Follow appropriate
directions
below for type of duct
run you install.
a.) Wall Cap Discharge;
(FIG. 7) Use saber saw
or keyhole
saw to cut hole slightly
larger than
duct size used so that duct will line up easily
with
damper/duct
conector
on hood.
Install
casing
strips if cap will be installed
on siding.
Attach required amount of duct to wall cap and
run duct back to hood. Fasten cap to wall and
caulk well.
b.) Roof Cap Discharge;
(FIG.
8) Cut a hole in
roof slightly larger than duct size being used.
Run ductwork
down to hood
location.
Leave
3/4" of duct projecting
above
roof surface
on
high side.
Trim
duct parallel
to roof pitch
and seal all
around duct with roof cement.
Carefully
trim shingles
and slide back of roof
sheet under shingles.
Nail roof sheet to roof un-
der shingles
at top two corners and two sides.
Nail sheet directly to roof in four places at bot-
tom.
Using
roof cement,
seal all nail
heads
and
shingles
which were cut or lifted. Do not seal
bottom edge of roof sheet.
INSTALL RANGE HOOD
I
WARNING
I
TURN OFF THE PROPER CIRCUIT AT THE SER-
VICE ENTRANCE
BEFORE WIRING THIS RANGE
HOOD.
1. Run electric wiring through
hole drilled in wall or
cabinet. Split wiring for 6" and install proper con-
nector for type of wire used. (FIG. 9)
2. Position
hood so that:
a.) Wiring
is routed
through
knockout
opening
(FIG. 10) (MX Series Only: Use grommet
sup
plied in parts bag.)
b.) Large part of keyhole slots fit over hood mount-
ing screws.
(FIG. 10)
c.) Damper/duct
connector
slides into ductwork.
(40000, 42000
and 42000D
hoods only)
3. Adjust hood so that hood front is flush with cabi-
net frame.
4. Tighten hood mounting
screws firmly.
5. Fasten wiring to hood with proper electrical
con-
nector for type of wire being used.
WARNING
ALL ELECTRICAL
CONNECTIONS
MUST BE tN
ACCORDANCE
WITH
LOCAL
CODES,
ORDI-
NANCES, OR NATIONAL ELECTRICAL
CODE. IF
YOU ARE UNFAMILIAR
WITH METHODS
OF IN-
STALLING
ELECTRICAL
WIRING, SECURE THE
SERVICES
OF A QUALIFIED
ELECTRICIAN.
6. Strip 1/2" of insulation
from wires. Connect
white
to white, black to black, and green to prepared
hole with green ground screw provided.
(FIG. 11 )
7. Replace wiring box cover and screw. Make sure
that all wiring
is safely contained
inside.
8. Install light (75 Watt maximum).
For easier instal-
lation, squeeze
plastic lens and remove
it from
hood. Remember
to reinstall
lens. (FIG.12)
9. Turn on power
and check
operation
of fan and
light. Make sure that damper
operates freely.
FIG. 5A
L__ _ °_
\
....
_.
:
I
\
f
I
,
'<_ ..........
l
7, .t !
/
/
\ _
_
_
__.i_ //_
FIEZA
OE
-'--
6///
AOERA
_i_l,
.. '
--t_
I
CENTER
LINE
I
' . / _"
]
=
,ooo W, TTEAOB
CENTROS ....
ANCHO
DEL EXTRACTOR
*'10-15/16" FOR 24" RANGE HOOD
10-15/16PLG. PARA EXTRACTOR DE 24PLG.
13-15/16"FOR30" _GE
HOOD
13-15/16PLG. PARA EXTRACTOR DE 30PLG.
16-15/16"FOR36" _GE
HOOD
16-15/16PLG. PARA EXTRACTOR DE 36PLG.
19-15/16"FOR42" _GE
HOOD
19-15/16PLG. PARA EXTRACTOR DE 42PLG.
FIG. 5B
MODELOS
40000
MODELO 42000
_._
FIG. 6
/
\
CENTROS
FIG. 7
SOFFIT
ALL CAP
CASQUETE
DE PARED
GABINETE
FIG. 8
ROOF CAP
CASQUETE
DE
CABINET
GABINETE
INSTALACION DEL DUCTO
(Esta
secci6n
es solamente
para
los extractores
modelos
40000 y 42000.
Los modelos
41000
pueden
saltarse
esta secci6n
y continuar
en la "INSTALACION
DEL EXTRACTOR'.')
NOTA
Estas instrucciones
seguir_n
los planes
descritos
en la p_g 2. Comience
a trabajar
del exterior
al in-
terior
para conectar
el ducto
con el extractor.
Para obtener
un mejor funcionamiento
del extrac-
tor, procure
que la salida
del ducto
sea la m&s
directa
y que tenga el menor numero
de codos.
No permita
que la salida del extractor
quede en un
desv_n. Si se forma una capa de grasa en el desv_n
puede ser peligroso
y causar un incendio.
Utilice
solamente
ductos
de metal.
NO USE
DUCTOS
DE PLASTtCO.
Ensamble
el ducto
firmemente
para que en caso
de que se prenda
debido
a la grasa, el fuego se contenga
dentro del
ducto
de metal. Coloque
cinta
de aislar
en todas
las conexiones
del ducto.
1. Siga las incicaciones
adecuadas
para el tipo de ducto
que vaya a instalar.
a.)
Salida del casquete
de pared: (FIG. 7) Utilice
un serruoho
o una sierra de calador
para cortar
un orificio
un poco m_ts grande
que el tama_o
del ducto, para poder acomodar
facilmente
el
ducto con el conector
del ducto/regulador
en el
extractor.
Si el casquete
se va a instalar
en un
lado, instale las tiras del marco. Fije la cantidad
requerida
del ducto en el casquete
de pared y
acomode
el ducto
en el extractor.
Ajuste
el
casquete
a la pared. Fijelo con un martillo. (Si la
pared es de concreto
u otro material, ejecute las
operaciones
necesarias
para obtener los mismos
resultados.)
b.)
Salida del casquete por el techo: (FIG. 8) Haga un
orificio en el techo, ligeramente
ma.s grande que
la circunferencia
del ducto que se esta usando.
Coloque
el ducto debajo
del lugar donde
va el
extractor. Deje que 3/4 pig. del ducto sobresalgan
per encima de la superficie en el lado alto del techo.
Ajuste el ducto paralelamente
con la inclinacion
del techo y selle alrededor
del tubo con cemento
para techos o tejados.
Empareje las tejas con cuidado y deslice la placa
del tejado que esta debajo de las tejas. Clave la
placa del tejado a la parte de techo que esta
bajo las tejas
en las dos esquinas
y los dos
lados superiores.
Clave la placa directamente
al tejado en cuatro extremos
en la parte inferior.
Utilizando
cemento
para tejado, selle todas las
cabezas
de los clavos
y las tejas
que fueron
cortadas
o levantadas.
No selle el extremo
infe-
rior de la placa
del tejado.
(Si el techo
es de
concreto
haga las operaciones
necesarias
para
obtener
los mismos
resultados.)
INSTALACION
DEL EXTRACTOR
i
ADVERTENCIA
I
DESCONECTE
EL CIRCUITO
EN LA ENTRADA
DE
SERVICIO
ANTES
DE CONECTAR
EL CABLEADO
DEL EXTRACTOR.
1. Pase el cableado
electrico
a traves de un orificio en
la pared o el gabinete.
Separe el cableado
a 6 pig. e
instale
el conector
apropiado
para el tipo de cable
usado. (FIG. 9)