SUN
EN
Once the brackets are mounted, secure
8
the SUN heater to the chosen panel,
making the boreholes in accordance with
the dimensions.
Ensure proper anchoring.
!
IMPORTANT
1- The electrical heating unit must be installed in areas which are protected from moisture and water.
2- Protect the cables from sharp objects, high temperatures, moisture and water.
3- For SAFETY REASONS, always turn off and disconnect the electrical equipment before any
intervention
4- DO NOT TOUCH the resistors when the unit is running.
5- TAKE CARE to not cover the air outputs when the unit is running.
CONNECTING EQUIPMENT
9
The SUN electronic units are supplied
with a series of connection cables
comprising 2 wires:
A - 0911320025 - Battery supply cabling
including 50 A fuse. "F".
B - 1500870019 - Power cabling.
!
IMPORTANT
THE CONNECTION CABLES MUST NOT
EXCEED A LENGTH OF 7m, the units are
supplied with 3m cable length.
Pay attention to the location of the unit and
ensure no elements which may damage the
operation or lead to overheating are introduced
through
the
windows
elements.
or
channelling
16
8
43 mm
Ø 7 mm
250 mm
9
A
9
B
9
F