TABLE B: LOGIC MENU (logic)
Logic
Default Definition
Automatic
ON
TCA
Closing Time
ON
Block Pulses
Ibl open
OFF
Impulse lock TCA
ibl TCA
OFF
2 step
2 step
ON
3 step
3 step
OFF
Pre-alarm
preal
hold to
OFF
Deadman
Run
Photocells
ON
Photoc. o pen
during opening
OFF
Rapid closing
fast cls
OFF
Photocell test
test phot
OFF
Master/slave
ster
OFF
Fixed code
fixed code
Remote control
ON
radio prog
programming
ON
SCA Alarm
alar sca
OFF
Reversing motion
change ot.
open-ti er
OFF
TIMER su OPEN
(special dip 2*)
*=Refer for universal handheld programmer.
28
- GIOTTO 30-50 S BT / GIOTTO 30-50 BT
INSTALLATION MANUAL
Cross
out
Description
setting
used
ON
Switches automatic closing on.
OFF
Switches automatic closing off.
ON
The start pulse has no effect during opening.
OFF
The start pulse has effect during opening or closing.
ON
The Start impulse has no effect during the TCA dwell period.
OFF
The Start impulse becomes effective during the TCA dwell period.
Enables the 2-step logic (prevails over
ON
the "3-step logic").
Disables the 2-step logic, activating the
OFF
4-step logic if the "3-step logic" is OFF.
Enables the 3-step logic (if the "2-step
ON
logic" is OFF).
Disables the 3-s6tep logic, activating the
4-step logic if the "2-step logic" is OFF.
OFF
ON
The flashing light comes on approx. 3 seconds before the motors start.
OFF
The flashing light comes on at the same time as the motors start.
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE
ON
control keys are kept pressed. The radio transmitter cannot be used.
OFF
Normal impulse operation.
When beam is broken, operation of the photocell is switched off during opening. During closing,
ON
movement is reversed immediately.
When beam is broken, photocells are active during both opening and closing. When beam is
OFF
broken during closing, movement is reversed only once the photocell is cleared.
Closes barrier after photocell disengagement, before waiting for the end of the TCA (automatic
ON
closing time) set.
OFF
Command not entered.
ON
Switches photocell testing on
Switches photocell testing off
OFF
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not
equipped with supplementary test contacts.
ON
Control panel is set up as the Master unit in a centralized serial connection system.
OFF
Control panel is set up as a Slave unit in a centralized serial connection system.
ON
Receiver is configured for operation in fixed-code mode.
OFF
Receiver is configured for operation in rolling-code mode.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has
already been memorized in standard mode via the radio menu.
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be
ON
memorized.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new
transmitters. This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters.
OFF
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
The SCA contact (terminals 21-22) behaves as follows:
- with barrier open and on opening: contact closed (warning light on)
ON
- with barrier closed:contact open: (warning light off)
- on closing: intermittent contact (blinking)
OFF
The SCA contact closes according to the modes set by the Alarm Time parameter.
ON
Change this parameter if the opening direction needs to be changed
OFF
Standard operating mode.
ON
Input between terminals 15-27 works as TIMER.
OFF
Input between terminals 15-27 works as OPEN.
https://appceso.com
Response to the START impulse
Barrier
2 steps
3 steps
closed
opens
opens
on closing
open
closes
closes
on opening
stop + TCA stop + TCA
after stop
opens
opens
4 steps
opens
stop
closes
opens