5. Operation
< Process for setting >
[1] To turn off air conditioner and change the remote
controller to "Fixed airflow direction mode"
1.Press ON/OFF button 1 to turn off the air conditioner.
.Press Fan Speed button 2 and Filter
seconds simultaneously and it becomes the fixed airflow direction
mode after a while.
"Fixed airflow direction mode" display
Air blows downward after it becomes
"fixed airflow direction mode".
[2] To select and identify the outlet to set
1.Press Set Temperature button 5 to change number with the outlet No.
blinking. Select outlet No. to set.
Unit No.
Up/Down air direction Refrigerant address No.
Outlet No.
Outlet No.3
Outlet No.2
.Press Filter
button 3 to send the information on remote controller.
3. Wait for 15 seconds. How does the air conditioner run?
→Only the air from the selected outlet blows downward.
→Go to step[3].
→Air from the wrong outlet blows downward.
→Repeat 1 and set again.
→All outlets are closed.
→The numbers of the air conditioner (refrigerant address No.,
Unit No.) are wrong. Refer to How to find air conditioner No..
[3] To fix air direction
1.Press Mode button (Return button) 4 to blink Up/Down air direction
indicater.
.Press Set Temperature button 5 until the direction to set is chosen.
3.Press Filter
button 3 to send the information on remote controller to
air conditioner.
4.Wait for 15 seconds. How does the air conditioner run?
→Airflow direction is set in the selected direction.
→The fixed setting completed (Go to step [4].)
→Airflow direction is set in the wrong direction.
→Repeat 2. and set again.
Up/Down air direction
Unit No.
Outlet No.
Air direction changes
This indicates NO FIXED SETTING(canceled)
8
button 3 for more than
Outlet No.4
MITSUBISHI
ELECTRIC
label
Outlet No.1
Note: "0" indicates
all outlets.
Refrigerant address No.
[4] To cancel "Fixed airflow direction mode"
1.Press ON/OFF button 1 to cancel "Fixed airflow direction mode".
It is also canceled by pressing Fan Speed button 2 and Filter
3 for more than seconds simultaneously.
2.Do not operate remote controller for 30 seconds after the "Fixed airflow
direction mode" is canceled. It does not accept even if it is operated.
button