The outer casing of the power tool is made from impact-
resistant plastic. The grips have a synthetic rubber cov-
ering.
Never operate the power tool when the ventilation slots
are blocked. Clean the ventilation slots carefully using
en

8.3 Service indicator

NOTE
The power tool is equipped with a service indicator.
Indicator

8.4 Cleaning the dust shield

Clean the dust shield on the chuck with a dry, clean
cloth at regular intervals. Clean the sealing lip by wiping it
carefully and then grease it again lightly with Hilti grease.
8.5 Maintenance
WARNING
Repairs to the electrical section of the power tool may
be carried out only by trained electrical specialists.
Wait approx. 1 minute to allow dissipation of residual

9 Troubleshooting

Fault
The power tool doesn't start.
10
a dry brush. Do not permit foreign objects to enter the
interior of the power tool. Clean the outside of the power
tool at regular intervals with a slightly damp cloth. Do
not use a spray, steam pressure cleaning equipment or
running water for cleaning. This may negatively affect the
electrical safety of the power tool.
Constant red light
Blinking red light
voltage before dismantling the power tool and removing
the electronics unit.
Check all external parts of the power tool for damage
at regular intervals and check that all controls operate
faultlessly. Do not operate the power tool if parts are
damaged or when the controls do not function faultlessly.
Have the appliance repaired by Hilti Service.
8.6 Checking the power tool after care and
After carrying out care and maintenance work on the
power tool, check that all protective and safety devices
are fitted and that they function faultlessly.
Possible cause
Initialization of the electronics is in
progress (takes up to approx. 4 sec.
after plugging in) or the electronic
restarting interlock has become acti-
vated after an interruption in the elec-
tric supply.
Interruption in the electric supply.
The supply cord or plug is defective.
The control switch is defective.
Generator with sleep mode.
End of service interval - servicing is due.
After the lamp lights for the first time,
the power tool may continue to be used
for several hours before the automatic
cut-out is activated. To ensure that the
power tool is always ready for use, it
should be returned to Hilti for servicing
in good time.
See section "Troubleshooting".
maintenance
Remedy
Switch the power tool off and on
again.
Plug in another electric appliance and
check whether it works.
Have it checked by a trained electrical
specialist and replaced if necessary.
Have it checked by a trained electrical
specialist and replaced if necessary.
Apply a load to the generator by con-
necting another appliance (e.g. a
lamp). Subsequently switch the power
tool off and on again.