Electrical Connections - WIKA O-10 Manual De Instrucciones

Transmisor de presión
Ocultar thumbs Ver también para O-10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Specifications

3.7 Electrical connections

Electrical safety
Short-circuit resistance:
Reverse polarity protection: U
Overvoltage protection:
Insulation voltage:
3.8 Materials
Non-wetted parts
Stainless steel 316L, PBT GF 30, Cable material from PVC
Wetted parts
Stainless steel 316L, 13-8 PH
3.9 Approvals, directives and certificates
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial appli-
cation)
Pressure equipment directive 97/23/EC
Approvals
cULus, GOST
RoHS conformity
Yes
For special model numbers, e.g. O-10000, please note the specifications stated on the delivery note.
For further specifications see WIKA data sheet PE 81.65 and the order documentation.
WIKA operating instructions pressure transmitter model O-10
S
vs. U -
+
vs. U -
B
DC 36 V
DC 750 V
GB
13

Publicidad

Tabla de contenido
loading

Tabla de contenido