Operating Instructions SATA spray master RP
Malfunction
Material splutters in
gravity flow cup.
Corrosion on air cap
thread, material pas-
sages (material con-
nection) or spray gun
body.
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at
fluid tip ("fluid tip aper-
ture").
12. Disposal
Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!
13. After Sales Service
For accessories, spare parts and technical support, contact your SATA
dealer.
Cause
Atomising air gets into
gravity flow cup via
paint channel. Fluid
tip not tightened suf-
ficiently. Air cap not
screwed on complete-
ly, air circuit clogged,
seat defective or noz-
zle set damaged.
Cleaning solution (wa-
tery) remains in the
gun for too long.
Unsuitable cleaning
solution.
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective action
Tighten, clean or re-
place parts.
Have gun body re-
placed. Heed cleaning
instructions (see chap-
ter 10).
Replace paint needle
seal.
Replace nozzle set (see
chapter 9.2).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 10).
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 10).
Replace nozzle set (see
chapter 9.2).
EN
133