Installing the air distribution ring
■ Replace the air distribution ring. The pin [8-3] of the air distribution ring
must be aligned properly.
■ Press air distribution ring in evenly.
■ Assemble the nozzle set (see 9.1).
After assembly, set the material flow rate as instructed in Chapter 8.2.
9.3. Replacing the paint needle packing
Replacement is required when material escapes from the self-adjusting
paint needle packing.
Removing the paint needle packing
■ Nozzle set removal (see 9.1).
■ Unscrew seal retainer [9-1] and remove from gun body.
■ Remove seal [9-2] and spring [9-3].
Installing the paint needle packing
■ Insert seal [9-2] and spring [9-3].
■ Attach seal retainer [9-1] to gun body.
■ Assemble the nozzle set (see 9.1).
After assembly, set the material flow rate as instructed in Chapter 8.2.
9.4. Replacing the air piston, air piston spring and air mi-
crometer
Danger!
Risk of injury due to loose air micrometer.
The air micrometer can fly out of paint spray gun uncontrolled if locking
screw is not tight.
→ Ensure air micrometer locking screw is tightly secured. Tighten, if
necessary.
Replacement is necessary if air escapes at the air nozzle or air
micrometer when the trigger has not been squeezed.
Removing the air piston, air piston spring and air micrometer
■ Unscrew locking screw [10-2] and remove from gun body.
■ Pull air micrometer [10-5] out of gun body.
■ Remove air piston [10-3] with air piston spring [10-4].
■ Remove trigger [10-6].
■ Unscrew packing screw and air piston rod [10-7] from gun body and
pull out to remove.