7.2.1 Normativas Atendidas
NORMAS DE SEGURIDAD.
NORMAS DE COMPATIBILIDAD
ELETROMAGNÉTICA (EMC).
NORMAS DE CONSTRUCCIÓN MECÁNICA.
7.3 DATOS MECÁNICOS
7.3.1 Peso
El peso líquido de la UR11 es de 286 kg (630,5 lb).
7.3.2 Dimensiones
Las dimensiones de la UR11 son presentadas en la
UL 508C - power conversion equipment.
UL 8340 - insulation coordination including clearances and creepage distances for
electrical equipment.
EN61800-5-1 - safety requirements electrical, thermal and energy.
EN 50178 - electronic equipment for use in power installations.
EN 60204-1 - safety of machinery. electrical equipment of machines. part 1: general
requirements.
Nota: para ter uma máquina em conformidade com essa norma, o fabricante da
máquina é responsável pela instalação de um dispositivo de parada de emergência e um
equipamento para seccionamento da rede.
EN 60146 (IEC 146) - semiconductor converters.
EN 61800-2 - adjustable speed electrical power drive systems - part 2: general
requirements - rating specifications for low voltage adjustable frequency AC power drive
systems.
EN 61800-3 - adjustable speed electrical power drive systems - part 3: EMC product
standard including specific test methods.
EN 55011 - limits and methods of measurement of radio disturbance characteristics of
industrial, scientific and medical (ISM) radio-frequency equipment.
CISPR 11 - industrial, scientific and medical (ISM) radio-frequency equipment -
Electromagnetic disturbance characteristics - limits and methods of measurement.
EN 61000-4-2 - electromagnetic compatibility (EMC) - part 4: testing and
measurement techniques - section 2: electrostatic discharge immunity test.
EN 61000-4-3 - electromagnetic compatibility (EMC) - part 4: testing and
measurement techniques - section 3: radiated, radio-frequency, electromagnetic field
immunity test.
EN 61000-4-4 - electromagnetic compatibility (EMC) - part 4: testing and
measurement techniques - section 4: electrical fast transient/burst immunity test.
EN 61000-4-5 - electromagnetic compatibility (EMC) - part 4: testing and
measurement techniques - section 5: surge immunity test.
EN 61000-4-6 - electromagnetic compatibility (EMC)- part 4: testing and measurement
techniques - section 6: immunity to conducted disturbances, induced by radiofrequency
fields.
EN 60529 - degrees of protection provided by enclosures (IP code).
UL 50 - enclosures for electrical equipment.
Figura 7.1 en la página
Especificaciones Técnicas
7-4.
7
UR11 | 7-3