2 Fixtures
Please be sure to observe the safety information in section 1
2.1
Load data
Figure 1
The choice of fixtures according to the following table and the safe execution of
thefixture is up to the person responsible for installation.
WARNING – Note load data:
The static load data (rounded up) of the wall arm with the appliance
mounted on it can be found in the table below.
The operating forces must be added to the static load data.
The stipulated regional safety factors, but at least factor 3, must
be takeninto account.
The applicable regional building provisions must be observed.
Maximum
Extension arm
length
[mm]
750
Figure 2
950
2.2
Fixtures
Due to the varying nature and load-bearing capacity of walls, it is not possible to
definitively recommend particular dowels. Find out from fixture manufacturers
about theuse of suitable, type-approved fixtures.
3 Mounting the wall bracket
Please be sure to observe the safety information in section 1.
3.1
Installation height and operating range
Mountend
appliance
Typ M41
Typ S32 / S32L
* = recommended installation height
-Figure 01
Maximum
Bending
appliance load
moment
[N]
MB [Nm]
120
340
120
390
Lower drill hole H
[mm]
2030
2080 *
2150
2030
2080 *
2150
15
.
Vertical weight
FG [N]
required to
240
245
-Figure 02
R [mm]
R [mm]
Extension arm 750 Extension arm 950
1810
1790
1750
1630
1600
1550
GB
D
D
D
Force
pull out
dowel
FD[N]
1800
2100
2010
1990
1950
1830
1800
1750