OPERATION
Hazardous voltage. Can shock, burn or cause
death. Do not handle a pump or pump motor with wet hands
or when standing on wet or damp surface, or in water.
Before attempting to check why a unit has stopped operating,
disconnect power from the unit.
1. The shaft seal depends on water for lubrication and cool-
ing. Do not operate the pump unless it is submerged in
water as seal may be damaged if allowed to run dry.
2. The pump will not remove all water. On a flat surface
Model No. R33SU will pump down to within 1/8" of the
pumping surface.
NOTICE: For continuous operation, the pump must be sub-
merged to prevent the motor from overheating.
.3
Figure 1: Typical uses for pump

TROUBLESHOOTING

SYMPTOM
POSSIBLE CAUSE(S)
Pump won't start
Pump is not plugged in.
or run.
Blown fuse.
Low line voltage.
Defective motor.
Pump operates but
Restricted discharge
delivers little or
(obstacle or ice in piping).
no water.
Restricted intake.
Low line voltage.
Worn or plugged impeller.
The anti-airlock hole is plugged.
WA861
Dewater flat roofs
Roofs
Empty flooded rooms
Basements
.3
3696 0500 NEW
AIRLOCKS
(FIGURE 2)
When a pump airlocks, it runs but does not move any water.
An airlock will cause the pump to overheat and fail. The pump
has a built in anti-airlock hole. See the exploded view on the
repair parts page for the location of the hole. Water leakage
from the anti-airlock hole is normal.
If you suspect an airlock, unplug the pump, clean out the
anti-airlock hole with a paper clip or a piece of wire, and
restart the pump.
Figure 2: Anti-airlock hole is located under volute;
remove screen as shown for access.
CORRECTIVE ACTION
Check and see if pump is plugged in to a proper outlet.
If blown, replace with fuse of proper size or reset breaker.
If voltage is under recommended minimum. Check size of
wiring from main switch on property. If OK, contact power
company or hydro authority.
Replace pump.
Remove pump and clean pump and piping.
Remove the pump and clean out the intake screen.
The voltage is under recommended minimum. Check size of
wiring from main switch on property. If OK, contact power
company or hydro authority.
Replace pump.
Turn off the pump, clean out the anti-airlock hole, and
restart the pump.
4
Anti-Airlock Valve
(Remove screen
and look under
pump for access)